Actions

Difference between revisions of "Atmospheric Components Quick Reference"

From Unofficial Stationeers Wiki

(Add Kit column.)
(Add Air Conditioner and Wall Cooler.)
Line 1: Line 1:
This is a quick reference to the traits of the various components of a piped-fluid network.
+
This is a quick reference to the various components of a piped-fluid network.
  
 
{| class="wikitable"
 
{| class="wikitable"
Line 22: Line 22:
 
|-
 
|-
 
| [[Kit (Atmospherics) Electrolyzer|Electrolyzer]] || [[Kit (Atmospherics)]] || 1 || 1 || Yes || Yes || Yes || 1,400W || From input [[water|H<sub>2</sub>O]], output mixed [[Oxygen|O<sub>2</sub>]] and [[Volatiles]].
 
| [[Kit (Atmospherics) Electrolyzer|Electrolyzer]] || [[Kit (Atmospherics)]] || 1 || 1 || Yes || Yes || Yes || 1,400W || From input [[water|H<sub>2</sub>O]], output mixed [[Oxygen|O<sub>2</sub>]] and [[Volatiles]].
 +
|-
 +
| [[Kit (Atmospherics) Air Conditioner|Air Conditioner]] || [[Kit (Atmospherics)]] || 1 || 2 || Yes || Yes || Yes || 7,000W, varies || Heat or cool a fluid: From input, split heat between right-temperature and wrong-temperature outputs.
 +
|-
 +
| [[Wall Cooler]] || [[Wall Cooler]] || space || 1 || Yes, for heat<sup>2</sup> || Yes, for heat<sup>2</sup> || Yes, for heat<sup>2</sup> || ? || Actively remove heat from a space into a pipe.
 
|-
 
|-
 
| [[Active Vent]] || [[Active Vent]] || colspan="2"|1 pipe, 1 space || Yes, reversable || Yes || Yes || 100W || Pump pressure between a space and a pipe.
 
| [[Active Vent]] || [[Active Vent]] || colspan="2"|1 pipe, 1 space || Yes, reversable || Yes || Yes || 100W || Pump pressure between a space and a pipe.
 
|-
 
|-
 
| [[Passive Vent]] || [[Passive Vent]] || colspan="2"|1 pipe, 1 space || No || No || No || - || Equalize pressure between a space and a pipe.
 
| [[Passive Vent]] || [[Passive Vent]] || colspan="2"|1 pipe, 1 space || No || No || No || - || Equalize pressure between a space and a pipe.
|-
 
| [[Wall Cooler]] || [[Wall Cooler]] || x || x || 1w || switch || comp || 100W || function
 
|-
 
| [[Kit (Atmospherics) Air Conditioner|Air Conditioner]] || [[Kit (Atmospherics)]] || x || x || 1w || switch || comp || 100W || function
 
 
|-
 
|-
 
| [[Gas Tank Storage]] || kit || x || x || 1w || switch || comp || 100W || function
 
| [[Gas Tank Storage]] || kit || x || x || 1w || switch || comp || 100W || function
Line 40: Line 40:
 
'''Kit''': The item used to build the component. All of these items are manufactured with a [[Hydraulic Pipe Bender]] or [[Fabricator]], except where noted.
 
'''Kit''': The item used to build the component. All of these items are manufactured with a [[Hydraulic Pipe Bender]] or [[Fabricator]], except where noted.
  
'''One-way''': Does the component prevent gas from flowing the wrong way, from output to input?
+
'''One-way''': Does the component prevent fluid from flowing the wrong way, from output to input?
  
'''Switched''': Does it prevent all gas flow when switched off or unpowered? All switched components can be switched either manually or using [[Kit (Logic I/O)|logic circuits]].
+
'''Switched''': Does it prevent all flow when switched off or unpowered? All switched components can be switched either manually or using [[Kit (Logic I/O)|logic circuits]].
  
 
'''Compressor''': Will it actively increase pressure in the output and decrease pressure in the input? If no, the component only allows pressure to change toward equilibrium between input and output.
 
'''Compressor''': Will it actively increase pressure in the output and decrease pressure in the input? If no, the component only allows pressure to change toward equilibrium between input and output.
  
 
'''Note 1:''' While the Pipe Gas Mixer will actively compress from output to input, it will stop when either input is empty, to preserve the mix ratio.
 
'''Note 1:''' While the Pipe Gas Mixer will actively compress from output to input, it will stop when either input is empty, to preserve the mix ratio.
 +
 +
'''Note 2:''' The Wall Cooler's one-way, switched, and "compressor" qualities apply only to the heat exchange. It does not directly affect the pressure or flow in its attached pipe.

Revision as of 11:55, 26 May 2020

This is a quick reference to the various components of a piped-fluid network.

Component Kit Inputs Outputs One-way? Switched? Compressor? Max. Power Primary Function
Pipe (various shapes) Pipes 2-6 generic No No No - Provide a pathway.
Pipe Valve Pipe Valve 2 generic No Manual No - Open/close flow manually.
Pipe Digital Valve Pipe Digital Valve 2 generic No Yes No 25W Open/close flow using logic circuits.
Pipe Volume Pump Pipe Volume Pump 1 1 Yes Yes Yes 800W, varies Pump fluid at adjustable rate.
Pressure Regulator Pressure Regulator 1 1 Yes Yes Yes 100W Achieve target pressure at output.
Back Pressure Regulator Pressure Regulator 1 1 Yes Yes Yes 100W Achieve target pressure at input.
Pipe Gas Mixer Pipe Gas Mixer 2 1 Yes Yes Yes1 100W Combine two input mixes into one output mix, at an adjustable ratio.
Filtration Kit (Atmospherics) 1 2 Yes Yes Yes 5W Separate an input mix into a pure output and a "leftover" output.
Electrolyzer Kit (Atmospherics) 1 1 Yes Yes Yes 1,400W From input H2O, output mixed O2 and Volatiles.
Air Conditioner Kit (Atmospherics) 1 2 Yes Yes Yes 7,000W, varies Heat or cool a fluid: From input, split heat between right-temperature and wrong-temperature outputs.
Wall Cooler Wall Cooler space 1 Yes, for heat2 Yes, for heat2 Yes, for heat2  ? Actively remove heat from a space into a pipe.
Active Vent Active Vent 1 pipe, 1 space Yes, reversable Yes Yes 100W Pump pressure between a space and a pipe.
Passive Vent Passive Vent 1 pipe, 1 space No No No - Equalize pressure between a space and a pipe.
Gas Tank Storage kit x x 1w switch comp 100W function
Tank (Large and Small) kit x x 1w switch comp 100W function
Tank Connector kit x x 1w switch comp 100W function

Kit: The item used to build the component. All of these items are manufactured with a Hydraulic Pipe Bender or Fabricator, except where noted.

One-way: Does the component prevent fluid from flowing the wrong way, from output to input?

Switched: Does it prevent all flow when switched off or unpowered? All switched components can be switched either manually or using logic circuits.

Compressor: Will it actively increase pressure in the output and decrease pressure in the input? If no, the component only allows pressure to change toward equilibrium between input and output.

Note 1: While the Pipe Gas Mixer will actively compress from output to input, it will stop when either input is empty, to preserve the mix ratio.

Note 2: The Wall Cooler's one-way, switched, and "compressor" qualities apply only to the heat exchange. It does not directly affect the pressure or flow in its attached pipe.