Actions

Guide (Airlock) Atmosphere to Atmosphere

From Unofficial Stationeers Wiki

Revision as of 04:05, 27 August 2024 by 1.147.71.210 (talk) (spelling)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)


Description[edit]

An Atmosphere to Atmosphere Airlock is a Room that can evacuate its internal volume and refill it with either of the two differing Atmospheres it connects. It has two airtight Portals which do not open simultaneously. An Atmosphere to Atmosphere Airlock allows passage between two environments without the exchange of Gases or Pressure.

An Atmosphere to Atmosphere Airlock can be controlled automatically using a Circuitboard (Advanced Airlock) installed within a Console which will refer to each of the two separated environments as either "interior" or "exterior".

When activated with the interior-portal open, the system will automatically close the interior-portal and will activate the interior-Active-Vent to try to evacuate the interior-atmosphere from the airlock chamber. Once a total vacuum is achieved within all of the Large Grid Volumes in which selected Gas Sensors reside, the airlock will activate the exterior-Active-Vent to try to pressurize the chamber with exterior-atmosphere. Only after the internal pressure within all of the Large Grid Volumes in which selected Gas Sensors reside equals or exceeds the "External ###Pa" specified in the Circuitboard's settings will the exterior-portal automatically open.

When activated with the exterior-portal open, a similar process to the above is executed, swapping interior for exterior, exterior for interior, and the final airlock pressure governed by the "Internal ###Pa" setting instead.

Materials[edit]

Material requirements for a minimum Atmosphere to Atmosphere Airlock are:

Construction[edit]

A minimum Atmosphere to Atmosphere Airlock can be constructed using the following instructions:

  1. Place two Portals one Large Grid apart with the power and data ports facing into the airlock's interior.
  2. Using the Labeller, rename each portal as "Interior-Door" and "Exterior-Door" appropriately.
  3. Ensure the "Exterior-Door" is OPEN, and the "Interior-Door" is CLOSED.
  4. Enclose the four remaining sides of the airlock chamber with airtight Frames, Walls, or Windows.
  5. Place Console, Active Vents, Gas Sensor, and optional Flashing Light and Power Controller somewhere within the airlock's interior.
  6. Ensure all placed devices are attached to the same Wire Network including the portals' power and data ports.
  7. Ensure the airlock's wire network is connected to an active Power Supply and all devices can receive power.
  8. Using the Labeller, rename each Active Vent as "Interior Vent" and "Exterior Vent" appropriately.
  9. Attach a Pipe Network to each Active Vent large enough to hold the volume of the airlock or pass it through to a Passive Vent placed in the "interior" or "exterior" environment.
  10. Ensure "interior" and "exterior" pipe networks are not connected together or to any other pipe networks.
    advanced airlock with 2 walls removed for better visibility
  11. Insert Circuitboard (Advanced Airlock) into the console, then place the Glass Sheet onto the console.
  12. Insert Data Disk into the side slot of Console then power on the Console.
    slot to insert data disk
  13. The following steps may be done with the game paused.
  14. Use the console's up and down arrows to scroll through the list of devices. Click to select. Click again to deselect if incorrect
  15. Find and click "Exterior-Door" followed by all caps and green "EXTERIOR". NOTE: SELECT THIS FIRST!
    make sure to click the exterior door and vent first
  16. Ensure the Exterior-Door's lock-indicator has turned from green to red.
  17. Find and click "Exterior-Vent" followed by all caps and green "EXTERIOR". NOTE: SELECT THIS SECOND!
  18. Find and click "Interior-Door" followed by all caps and green "INTERIOR".
  19. Ensure the Interior-Door's lock-indicator has turned from green to red.
  20. Find and click "Interior-Vent" followed by all caps and green "INTERIOR".
  21. Find and click "Gas Sensor" followed by all caps and green "SENSOR".
  22. Find and click "Flashing Light" followed by all caps and green "LIGHT". (optional)
  23. Toward the top left of the Console find and click "External ###Pa". Set to match the exterior-environment's typical pressure. (optional)
  24. Toward the top right of the Console find and click "Internal ###Pa". Set to match the interior-environment's typical pressure. (optional)
    set pressures appropriate to each side
  25. Remove Data Disk from the side slot of Console.


If there is an error the console screen will say so and the power light will flash yellow.

Console Slaves[edit]

Additional consoles are useful when airlocks become large or remote control is desired. Multiple Console Slaves can be attached using the following instructions:

  1. Using the Labeller, rename the original Console as "Master Console".
  2. Place additional consoles such that they all attached to the same Wire Network connected to the "Master Console".
  3. Using the Labeller, rename each additional console as "Slave Console 1", "Slave Console 2" ...
  4. Insert Circuitboard (Advanced Airlock) into each additional console, then place a Glass Sheet onto the additional consoles.
  5. Insert Data Disk into the side slot of the powered on "Master Console".
  6. Use the "Master Console's" up and down arrows to scroll through the list of devices. Click to select. Click again to deselect if incorrect
  7. Find and click "Slave Console #" followed by all caps and green "MAKE SLAVE" for each additional console.
  8. Remove Data Disk from the side slot of "Master Console".
  9. Power on each additional console.


If there is an error the console screen will say so and the power light will flash yellow.

Troubleshooting[edit]

When powered, all associated doors and vents are locked, preventing their manual use even when power is subsequently denied. This can be a problem when trapped within an airlock during a power outage. Best practise is to ensure the airlock's wire network is connected to an emergency Power Supply such as a Battery Cell equipped Power Controller.

If the "External #Pa" or "Internal #Pa" are set to 0, the corresponding pressurization phase will be skipped, speeding up the cycle time, but can result in large wind currents when doors open.

A pressurization phase will stall if there is not enough gas available to the interior or exterior Active Vent to reach the set "Internal #Pa" or "External #Pa" specified in the Circuitboard's settings. Such stalled pressurization can be skipped by clicking the yellow "Cancel Pressurize" button on a console.

A depressurization phase will stall if a complete vacuum cannot be achieved within the Large Grid Volumes in which all selected Gas Sensors reside. Such stalled depressurization can be skipped by clicking the yellow "Cancel Depressurize" button on a console, but atmospheric mixing may occur. In larger airlocks, ensure there is one Gas Sensor per Large Grid to prevent premature repressurization and the resulting mixture of interior and exterior atmospheres.

The setup of slave consoles may still be bugged in such a way that after initial setup the slave console will show the config of an airlock, but be grayed out and not accept any input. It has been noted in several community posts that saving the game, quitting out of the game, and then reloading the save will allow the slave consoles to work after the reload.

See Also[edit]