Liquid Digital Valve
From Unofficial Stationeers Wiki
Properties | |
---|---|
Stacks | No |
Recipe | |
Created With | Hydraulic Pipe Bender, Fabricator |
Cost | 2g Copper, 5g Steel, 3g Invar |
Contents
Liquid Digital Valve
Description
A valve which can be operated by logic network. Switching its "On" variable to 1 causes the valve to be fully open, switching to 0 closes the valve to completely close. Power usage: 0 Watts when off. 5 Watts when on.
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Lock | Boolean | Locks the Liquid Digital Valve, when set to 1. Unlocks it, when set to 0. |
Setting | Float | Does not function. |
On | Boolean | Turns the Liquid Digital Valve on, when set to 1. Turns it off, when set to 0. |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Maximum | Integer | Returns 100. (Assumption) Returns the maximum throughput percentage of the Liquid Digital Valve. |
Lock | Boolean | Returns whether the Liquid Digital Valve is locked. (0 for no, 1 for yes) |
Error | Boolean | Returns whether the Liquid Digital Valve is currently flashing an error. (0 for no, 1 for yes) |
Setting | Float | Returns a range from 0.0 to 100.0. Does not function. (Assumption) Returns the percentage of opening of the Liquid Digital Valve. |
RequiredPower | Integer | Returns the current amount of power needed for the Liquid Digital Valve. |
Ratio | Float | Returns a range from 0.0 to 1.0. Does not function. (Assumption) Returns the differential in pressure between the sides of the Liquid Digital Valve. |
Prefab Hash | Integer | (Assumption) Returns (-517628750) a unique type identifier for the Liquid Digital Valve. |
Power | Boolean | Returns whether the Liquid Digital Valve is receiving power and is turned on. (0 for no, 1 for yes) |
On | Boolean | Returns whether the Liquid Digital Valve is set to on. (0 for no, 1 for yes) |