Pipe Volume Pump
From Unofficial Stationeers Wiki
Constructing Options | Volume Pump |
---|---|
Properties | |
Stacks | Yes (5) |
Recipes | |
Hydraulic Pipe Bender | 5g Iron, 2g Gold, 3g Copper |
Logic | |
Item Hash | -1766301997 |
Item Name | ItemPipeVolumePump |
Logic Classes |
SlotClass.None SortingClass.Kits |
File:StructureVolumePump.png | |
Operation | |
---|---|
Power Usage | Setting * 20W |
Prefab Hash | -321403609 |
Prefab Name | StructureVolumePump |
Construction | |
Placed with | Kit (Volume Pump) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Volume Pump) |
The volume pump pumps pumpable gases. It also separates out pipe networks into separate networks.
- Stationpedia
Description
Used to pump gasses throughout a pipe, featuring an adjustable valve 0-10 Liters and requiring power (20W per Liter). All the gasses in the pipes behind it will be completely pushed in front of it when powered, and blocks any flow of gasses in either direction when unpowered.
Note that valve settings are for the rate at which the pump operates, in volume per tick (0.5 seconds).
To calculate the moles per tick, use the following equation: n = (P * V) / (R * T)
Where:
- P = Input pressure
- V = The volume you set
- n = Moles per tick
- R = Gas constant (8.3144)
- T = Input temperature (in Kelvin)
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).
Click here to see/hide all the data network properties
Parameter Name | Data Type | Access | Value | Description | ||
---|---|---|---|---|---|---|
Power | Boolean | Read
|
0 | Unpowered | Can be read to return if the Volume Pump is correctly powered or not, set via the power system, return 1 if powered and 0 if not | |
1 | Powered | |||||
Error | Boolean | Read
|
0 | 1 if device is in error state, otherwise 0 | ||
1 | Error | |||||
Lock | Boolean | Read Write
|
0 | Unlocked | Disable manual operation of the Volume Pump. | |
1 | Locked | |||||
Setting | Integer | Read Write
|
0.0 to 10.0 | |||
Maximum | Float | Read
|
||||
Ratio | Float | Read
|
0.0 to 1.0 | |||
On | Boolean | Read Write
|
0 | Off | The current state of the Volume Pump. | |
1 | On | |||||
RequiredPower | Integer | Read
|
||||
PrefabHash | Integer | Read
|
||||
ReferenceId | Integer | Read
|
||||
NameHash | Integer | Read
|