Blast Doors
From Unofficial Stationeers Wiki
Revision as of 18:15, 13 November 2023 by Eleftherios (talk | contribs) (Added some information about the construction stages)
Operation | |
---|---|
Power Usage | 25W |
Burst Pressure | Infinite |
Construction | |
Placed with | Kit (Blast Door) |
Placed on | Large Grid |
Stage 1 | |
Next Stage Construction | |
Constructed with tool | Welding Torch |
Constructed with item | 3 x Steel Sheets |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Blast Door) |
Stage 2 | |
Next Stage Construction | |
Constructed with tool | Crowbar |
Constructed with item | 3 x Glass Sheets |
Deconstruction | |
Deconstructed with | (Not checked) |
Item received | 3 x Steel Sheets |
Stage 3 | |
Deconstruction | |
Deconstructed with | (Not checked) |
Item received | 3 x Steel Sheets |
Contents
Purpose
A Blast Door is a powered Portal that will withstand extreme forces.
Characteristics
- It has no limit to the Pressure it can constrain.
- It has a very high resistance to Damage.
- It consumes 25W of Power per Tick.
- It can be used as an Airlock portal.
- It has a separate Power Port and Data Port.
- It has indicator lights.
- If both unlocked and unpowered, it can be manually operated using a Crowbar.
- If enslaved by a regular or a advanced airlock circuit, it cannot be operated manually.
As long as the door is both unlocked and unpowered, it can be manually operated using a crowbar.
User Interface
A Blast Door provides the following user interface:
Name | Type | Function |
---|---|---|
Lock | Indicator | Turns red when locked and green when unlocked |
Since a Blast Door has no keypads to operate, they must be controlled by one of:
- Circuitboard (Advanced Airlock)
- Circuitboard (Airlock)
- Door Control
- Logic Writer
- Motherboard (Logic) in a Computer
Construction
A Blast Door is constructed using 1 x Kit (Blast Door).
Deconstruction
A Blast Door can be deconstructed at any time using a Hand Drill.
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Open | Boolean | Opens the Blast Door when set to 1. Closes it when set to 0. |
Lock | Boolean | Locks the Blast Door when set to 1. Unlocks it when set to 0. |
On | Boolean | Turns the Blast Door on when set to 1. Turns it off when set to 0. |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Blast Door is turned on and receives power. (0 for no, 1 for yes) |
Open | Boolean | Returns whether the Blast Door is open. (0 for no, 1 for yes) |
Lock | Boolean | Returns whether the Blast Door is locked. (0 for no, 1 for yes) |
On | Boolean | Returns whether the Blast Door is turned on. (0 for no, 1 for yes) |
RequiredPower | Integer | Returns the current amount of power, required by the Blast Door, in watts. |