Kit (Switch)
From Unofficial Stationeers Wiki
Contents
Data Network Properties
These are all Data Network properties of this device.
| Recipe | |
|---|---|
| Created With | Electronics Printer, Fabricator |
| Cost | 1g Gold, 1g Copper |
![]() | |
| Operation | |
|---|---|
| Construction | |
| Placed with | Kit (Logic Switch) |
| Placed on | Small Grid |
| Stage 1 | |
| Deconstruction | |
| Deconstructed with | Hand Drill |
| Item received | Kit (Logic Switch) |
![]() | |
| Operation | |
|---|---|
| Construction | |
| Placed with | Kit (Logic Switch) |
| Placed on | Small Grid |
| Stage 1 | |
| Deconstruction | |
| Deconstructed with | Hand Drill |
| Item received | Kit (Logic Switch) |
![]() | |
| Operation | |
|---|---|
| Construction | |
| Placed with | Kit (Logic Switch) |
| Placed on | Small Grid |
| Stage 1 | |
| Deconstruction | |
| Deconstructed with | Hand Drill |
| Item received | Kit (Logic Switch) |
![]() | |
| Operation | |
|---|---|
| Construction | |
| Placed with | Kit (Logic Switch) |
| Placed on | Small Grid |
| Stage 1 | |
| Deconstruction | |
| Deconstructed with | Hand Drill |
| Item received | Kit (Logic Switch) |
Switch
The Logic Switch gives players the ability to add controls to control circuits without requiring tools. Toggles output value between 0 and 1.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
| Parameter Name | Data Type | Description |
|---|---|---|
| Lock | Boolean | Prevents using the switch when set to 1 (not working as of v0.2.2891.14453) |
| Open | Boolean | Set the current switch state |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
| Output Name | Data Type | Description |
|---|---|---|
| Lock | Boolean | Gets the current lock state |
| Setting | Boolean | |
| PrefabHash | String | |
| Open | Boolean | Gets the current state |
Connectors
- Top: Data Output
- Bottom: Data Output
Lever
Toggles output value between 0 and 1.
Connectors
- Top: Data Output
- Bottom: Data Output
Button
Sends a pulse of 0.5 seconds long of value 1.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
| Parameter Name | Data Type | Description |
|---|---|---|
| Activate | Boolean | Sets the button setting to 1 |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
| Output Name | Data Type | Description |
|---|---|---|
| Activate | Boolean | Returns 1 if the activate state was just set by a write or IC |
| Setting | Boolean | Gets the current value of the button |
| PrefabHash | String |
Connectors
- Top: Data Output
- Bottom: Data Output
Dial
Allows user to select a value between 0 and the maximum set by use of screws.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
| Parameter Name | Data Type | Description |
|---|---|---|
| Mode | Boolean | Sets the maximum value you can set when using the dial |
| Setting | Boolean | Sets the current value of the dial |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
| Output Name | Data Type | Description |
|---|---|---|
| Mode | Boolean | Gets the maximum value you can set when using the dial |
| Setting | Boolean | Get the current value of the dial |
| PrefabHash | String | |
| Ratio | Integer |
Connectors
- Bottom: Data Output
Screws
- Bottom Left: Decrease maximum possible value to be set by dial.
- Bottom Right: Increase maximum possible value to be set by dial.