Actions

Difference between revisions of "Atmospheric Components Quick Reference"

From Unofficial Stationeers Wiki

(Add regulators.)
(Add pump.)
Line 6: Line 6:
 
|-
 
|-
 
| [[Pipes|Pipe]] (various shapes) || colspan="2"|2-6 generic || No || No || No || - || Provide a pathway.
 
| [[Pipes|Pipe]] (various shapes) || colspan="2"|2-6 generic || No || No || No || - || Provide a pathway.
|-
 
| [[Active Vent]] || colspan="2"|1 pipe, 1 space || Yes, reversable || Yes || Yes || 100W || Pump gas between a space and a pipe.
 
|-
 
| [[Passive Vent]] || colspan="2"|1 pipe, 1 space || No || No || No || - || Equalize gas between a space and a pipe.
 
 
|-
 
|-
 
| [[Pipe Valve]] || colspan="2"|2 generic || No || Manual || No|| -|| Open/close flow manually.
 
| [[Pipe Valve]] || colspan="2"|2 generic || No || Manual || No|| -|| Open/close flow manually.
 
|-
 
|-
 
| [[Pipe Digital Valve]] || colspan="2"|2 generic || No || Yes || No || 25W || Open/close flow using logic circuits.
 
| [[Pipe Digital Valve]] || colspan="2"|2 generic || No || Yes || No || 25W || Open/close flow using logic circuits.
 +
|-
 +
| [[Pipe Volume Pump]] || 1 || 1 || Yes || Yes || Yes || 800W, varies || Pump fluid at adjustable rate.
 
|-
 
|-
 
| [[Pressure_Regulator#Pressure_Regulator|Pressure Regulator]] || 1 || 1 || Yes || Yes || Yes || 100W || Achieve target pressure at output.
 
| [[Pressure_Regulator#Pressure_Regulator|Pressure Regulator]] || 1 || 1 || Yes || Yes || Yes || 100W || Achieve target pressure at output.
Line 19: Line 17:
 
| [[Pressure_Regulator#Back_Pressure_Regulator|Back Pressure Regulator]] || 1 || 1 || Yes || Yes || Yes || 100W || Achieve target pressure at input.
 
| [[Pressure_Regulator#Back_Pressure_Regulator|Back Pressure Regulator]] || 1 || 1 || Yes || Yes || Yes || 100W || Achieve target pressure at input.
 
|-
 
|-
| [[Pipe Volume Pump]] || x || x || 1w || switch || comp || 100W || function
+
| [[Active Vent]] || colspan="2"|1 pipe, 1 space || Yes, reversable || Yes || Yes || 100W || Pump pressure between a space and a pipe.
 +
|-
 +
| [[Passive Vent]] || colspan="2"|1 pipe, 1 space || No || No || No || - || Equalize pressure between a space and a pipe.
 
|-
 
|-
 
| [[Pipe Gas Mixer]] || x || x || 1w || switch || comp || 100W || function
 
| [[Pipe Gas Mixer]] || x || x || 1w || switch || comp || 100W || function

Revision as of 09:06, 26 May 2020

This is a quick reference to the traits of the various components of a piped-fluid network.

Component Inputs Outputs One-way? Switched? Compressor? Max. Power Primary Function
Pipe (various shapes) 2-6 generic No No No - Provide a pathway.
Pipe Valve 2 generic No Manual No - Open/close flow manually.
Pipe Digital Valve 2 generic No Yes No 25W Open/close flow using logic circuits.
Pipe Volume Pump 1 1 Yes Yes Yes 800W, varies Pump fluid at adjustable rate.
Pressure Regulator 1 1 Yes Yes Yes 100W Achieve target pressure at output.
Back Pressure Regulator 1 1 Yes Yes Yes 100W Achieve target pressure at input.
Active Vent 1 pipe, 1 space Yes, reversable Yes Yes 100W Pump pressure between a space and a pipe.
Passive Vent 1 pipe, 1 space No No No - Equalize pressure between a space and a pipe.
Pipe Gas Mixer x x 1w switch comp 100W function
Wall Cooler x x 1w switch comp 100W function
Air Conditioner x x 1w switch comp 100W function
Electrolyzer x x 1w switch comp 100W function
Filtration x x 1w switch comp 100W function
Gas Tank Storage x x 1w switch comp 100W function
Tank (Large and Small) x x 1w switch comp 100W function
Tank Connector x x 1w switch comp 100W function

One-way: Does the component prevent gas from flowing the wrong way, from output to input?

Switched: Does it prevent all gas flow when switched off or unpowered?

Compressor: Will it actively increase pressure in the output and decrease pressure in the input? If no, the component only allows pressure to change toward equilibrium between input and output.