m (Used temperature, pressure, and presumed volume of 64L of the gas canister to calculate how many moles of gas should be in the test canister, and Quantity readout matched with this calculated value. So I changed the description of the Quantity value.)
Line 43: Line 43:
 
| RatioWater || Float || Returns a range from 0.0 to 1.0. Returns the percentage ratio of the amount of water in a gas in a Gas Canister in the Gas Tank Storage.
 
| RatioWater || Float || Returns a range from 0.0 to 1.0. Returns the percentage ratio of the amount of water in a gas in a Gas Canister in the Gas Tank Storage.
 
|-
 
|-
| Quantity || Float || (Unknown, full tank shows 150, assumed is amount of gas in liters.)
+
| Quantity || Float || (Number of moles of gas in the canister (as of Nov 2019))
 
|}
 
|}

Revision as of 17:56, 4 November 2019


Kit (Canister Storage)
Gas tank storage laying on a ground
Recipe
Created With Hydraulic Pipe Bender
Cost 5g Iron
Gas Tank Storage
Full and empty gas tank storage
Construction
Placed with Kit (Canister Storage)
Placed on Small Grid, On Frames
Stage 1
Deconstruction
Deconstructed with Wrench
Item received Kit (Canister Storage)

Gas tank storage is a part of piping that allows Gas Canister filling and storage.

Usage

Mount on an Iron Frame connected to the pipe, insert Gas Canister inside, connect through piping to any gas output (such as Furnace rear output).

Data Network Properties

These are all Data Network properties of this device.

Data Parameters

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).

Click here to see/hide all the data network properties
empty
Parameter Name Data Type Access Value Description

Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Pressure Float Returns the amount of pressure of the Gas Canister in the Gas Tank Storage, in pascal.
Temperature Float Returns the temperature of the gas inside a Gas Canister in the Gas Tank Storage, in kelvin.
RatioOxygen Float Returns a range from 0.0 to 1.0. Returns the percentage ratio of the amount of oxygen in a gas in a Gas Canister in the Gas Tank Storage.
RatioCarbonDioxide Float Returns a range from 0.0 to 1.0. Returns the percentage ratio of the amount of carbon dioxide in a gas in a Gas Canister in the Gas Tank Storage.
RatioNitrogen Float Returns a range from 0.0 to 1.0. Returns the percentage ratio of the amount of nitrogen in a gas in a Gas Canister in the Gas Tank Storage.
RatioPollutant Float Returns a range from 0.0 to 1.0. Returns the percentage ratio of the amount of pollutant in a gas in a Gas Canister in the Gas Tank Storage.
RatioVolatiles Float Returns a range from 0.0 to 1.0. Returns the percentage ratio of the amount of volatiles in a gas in a Gas Canister in the Gas Tank Storage.
RatioWater Float Returns a range from 0.0 to 1.0. Returns the percentage ratio of the amount of water in a gas in a Gas Canister in the Gas Tank Storage.
Quantity Float (Number of moles of gas in the canister (as of Nov 2019))