Difference between revisions of "Pressurant Valve"
From Unofficial Stationeers Wiki
Emilgardis (talk | contribs) (cleanup pressurant valve) |
|||
Line 1: | Line 1: | ||
<translate> | <translate> | ||
<!--T:1--> | <!--T:1--> | ||
− | {{ | + | {{Structurebox |
− | + | | name = Pressurant Valve | |
− | + | | image = [[File:Pressurant Valve.png]] | |
+ | | prefab_hash = 23052817 | ||
+ | | prefab_name = StructurePressurantValve | ||
+ | | power_usage = 100W | ||
+ | | placed_on_grid = Small Grid | ||
+ | | decon_with_tool1 = [[Hand Drill]] | ||
+ | | placed_with_item = [[Kit (Pressure Regulator)]] | ||
+ | | item_rec1 = [[Kit (Pressure Regulator)]] | ||
}} | }} | ||
− | |||
==Description== <!--T:2--> | ==Description== <!--T:2--> | ||
+ | <blockquote><q>Pumps gas into a liquid pipe in order to raise the pressure</q><br> | ||
+ | '''- Stationpedia'''</blockquote> | ||
<!--T:3--> | <!--T:3--> | ||
− | + | ||
− | |||
See also [[Purge Valve]] which does quasi the opposite. | See also [[Purge Valve]] which does quasi the opposite. | ||
{{Data Network Header}} | {{Data Network Header}} | ||
{{Data Parameters| | {{Data Parameters| | ||
− | {{Data Parameters/row|Power|Boolean|w=0|Can be read to return if the | + | {{Data Parameters/row|Power|Boolean|w=0|Can be read to return if the Pressurant Valve is correctly powered or not, set via the power system, return 1 if powered and 0 if not|multiple=2|0|Unpowered|1|Powered}} |
{{Data Parameters/row|Error|Boolean|w=0|1 if device is in error state, otherwise 0|multiple=2|0|<p></p>|1|Error}} | {{Data Parameters/row|Error|Boolean|w=0|1 if device is in error state, otherwise 0|multiple=2|0|<p></p>|1|Error}} | ||
− | {{Data Parameters/row|Lock|Boolean|Disable manual operation of the | + | {{Data Parameters/row|Lock|Boolean|Disable manual operation of the Pressurant Valve.|multiple=2|0|Unlocked|1|Locked}} |
− | {{Data Parameters/row|Setting|Integer | + | {{Data Parameters/row|Setting|Integer|A variable setting that can be read or written.|0.0 to 60795.0}} |
− | {{Data Parameters/row|Maximum| | + | {{Data Parameters/row|Maximum|Float|w=0|Maximum setting of the Pressurant Valve}} |
{{Data Parameters/row|Ratio|Float|w=0|Context specific value depending on device, 0 to 1 based ratio|0.0 to 1.0}} | {{Data Parameters/row|Ratio|Float|w=0|Context specific value depending on device, 0 to 1 based ratio|0.0 to 1.0}} | ||
− | {{Data Parameters/row|On|Boolean|The current state of the | + | {{Data Parameters/row|On|Boolean|The current state of the Pressurant Valve.|multiple=2|0|Off|1|On}} |
− | {{Data Parameters/row|RequiredPower|Integer|w=0|Idle operating power quantity, does not necessarily include extra demand power}} | + | {{Data Parameters/row|RequiredPower|Integer|w=0|Idle operating power quantity, does not necessarily include extra demand power}} |
{{Data Parameters/row|PrefabHash|Integer|w=0|The hash of the structure}} | {{Data Parameters/row|PrefabHash|Integer|w=0|The hash of the structure}} | ||
{{Data Parameters/row|ReferenceId|Integer|w=0|Unique Reference Identifier for this object}} | {{Data Parameters/row|ReferenceId|Integer|w=0|Unique Reference Identifier for this object}} |
Revision as of 05:19, 10 July 2024
Operation | |
---|---|
Power Usage | 100W |
Prefab Hash | 23052817 |
Prefab Name | StructurePressurantValve |
Construction | |
Placed with | Kit (Pressure Regulator) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Pressure Regulator) |
Description
Pumps gas into a liquid pipe in order to raise the pressure
- Stationpedia
See also Purge Valve which does quasi the opposite.
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).
Click here to see/hide all the data network properties
Parameter Name | Data Type | Access | Value | Description | ||
---|---|---|---|---|---|---|
Power | Boolean | Read
|
0 | Unpowered | Can be read to return if the Pressurant Valve is correctly powered or not, set via the power system, return 1 if powered and 0 if not | |
1 | Powered | |||||
Error | Boolean | Read
|
0 | 1 if device is in error state, otherwise 0 | ||
1 | Error | |||||
Lock | Boolean | Read Write
|
0 | Unlocked | Disable manual operation of the Pressurant Valve. | |
1 | Locked | |||||
Setting | Integer | Read Write
|
0.0 to 60795.0 | |||
Maximum | Float | Read
|
||||
Ratio | Float | Read
|
0.0 to 1.0 | |||
On | Boolean | Read Write
|
0 | Off | The current state of the Pressurant Valve. | |
1 | On | |||||
RequiredPower | Integer | Read
|
||||
PrefabHash | Integer | Read
|
||||
ReferenceId | Integer | Read
|
||||
NameHash | Integer | Read
|