Difference between revisions of "Kit (Atmospherics) Electrolyzer"
From Unofficial Stationeers Wiki
Ipottinger (talk | contribs) m (add missing translation tag) |
m (paintability) |
||
Line 6: | Line 6: | ||
| image = [[File:Electrolyzer front.png]] | | image = [[File:Electrolyzer front.png]] | ||
| power_usage = 1200W | | power_usage = 1200W | ||
+ | | paintable = Yes | ||
| placed_with_item = [[Kit (Atmospherics)]] | | placed_with_item = [[Kit (Atmospherics)]] | ||
| placed_on_grid = Small Grid | | placed_on_grid = Small Grid |
Revision as of 21:38, 28 June 2022
Paintable | Yes |
---|---|
Operation | |
Power Usage | 1200W |
Construction | |
Placed with | Kit (Atmospherics) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Atmospherics) |
Contents
Purpose
An Electrolyzer is a powered Atmospheric processor used to separate water (H2O) into H2 and O2. Guide (Electrolyzer) provides additional information regarding the function, construction, and operation of an Electrolyzer.
Characteristics
- It has a manual power switch.
- It consumes #W of Power per Tick when idle.
- It consumes a maximum of #kW of Power per Tick when active.
- It has a separate Power Port and Data Port.
- It has a pipe port (labelled "Input") for the water that will be electrolyzed.
- It has a pipe port (labelled "Output") for the produced H2 + O2 gas mixtured.
- It outputs a perfect Fuel mixture of 66.6% H2 + 33.3% O2.
User Interface
An Electrolyzer provides the following user interface:
Name | Type | Function |
---|---|---|
On/Off | Switch | Switches Electrolyzer between turned on or turned off. |
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Lock | Boolean | Locks the Electrolyzer when set to 1. Unlocks it when set to 0. |
On | Boolean | Powers on the Electrolyzer on when set to 1. Powers off when set to 0. |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Electrolyzer is turned on and receives power. (0 for no, 1 for yes) |
Error | Boolean | Returns whether the Electrolyzer is flashing an error. (0 for no, 1 for yes) |
Lock | Boolean | Returns whether the Electrolyzer is locked. (0 for no, 1 for yes) |
On | Boolean | Returns whether the Electrolyzer is turned on. (0 for no, 1 for yes) |
RequiredPower | Integer | Returns the current amount of power in Watts required by the Electrolyzer. |