Actions

Difference between revisions of "Atmospheric Components Quick Reference"

From Unofficial Stationeers Wiki

(Add mixer and filter.)
(Add Electrolyzer.)
Line 20: Line 20:
 
|-
 
|-
 
| [[Kit (Atmospherics) Filtration|Filtration]] || 1 || 2 || Yes || Yes || Yes || 5W || Separate an input mix into a pure output and a "leftover" output.
 
| [[Kit (Atmospherics) Filtration|Filtration]] || 1 || 2 || Yes || Yes || Yes || 5W || Separate an input mix into a pure output and a "leftover" output.
 +
|-
 +
| [[Kit (Atmospherics) Electrolyzer|Electrolyzer]] || 1 || 1 || Yes || Yes || Yes || 1,400W || From input H<sub>2</sub>O, output mixed H<sub>2</sub> and O<sub>2</sub>.
 
|-
 
|-
 
| [[Active Vent]] || colspan="2"|1 pipe, 1 space || Yes, reversable || Yes || Yes || 100W || Pump pressure between a space and a pipe.
 
| [[Active Vent]] || colspan="2"|1 pipe, 1 space || Yes, reversable || Yes || Yes || 100W || Pump pressure between a space and a pipe.
Line 28: Line 30:
 
|-
 
|-
 
| [[Kit (Atmospherics) Air Conditioner|Air Conditioner]] || x || x || 1w || switch || comp || 100W || function
 
| [[Kit (Atmospherics) Air Conditioner|Air Conditioner]] || x || x || 1w || switch || comp || 100W || function
|-
 
| [[Kit (Atmospherics) Electrolyzer|Electrolyzer]] || x || x || 1w || switch || comp || 100W || function
 
 
|-
 
|-
 
| [[Gas Tank Storage]] || x || x || 1w || switch || comp || 100W || function
 
| [[Gas Tank Storage]] || x || x || 1w || switch || comp || 100W || function

Revision as of 09:40, 26 May 2020

This is a quick reference to the traits of the various components of a piped-fluid network.

Component Inputs Outputs One-way? Switched? Compressor? Max. Power Primary Function
Pipe (various shapes) 2-6 generic No No No - Provide a pathway.
Pipe Valve 2 generic No Manual No - Open/close flow manually.
Pipe Digital Valve 2 generic No Yes No 25W Open/close flow using logic circuits.
Pipe Volume Pump 1 1 Yes Yes Yes 800W, varies Pump fluid at adjustable rate.
Pressure Regulator 1 1 Yes Yes Yes 100W Achieve target pressure at output.
Back Pressure Regulator 1 1 Yes Yes Yes 100W Achieve target pressure at input.
Pipe Gas Mixer 2 1 Yes Yes Yes1 100W Combine two input mixes into one output mix, at an adjustable ratio.
Filtration 1 2 Yes Yes Yes 5W Separate an input mix into a pure output and a "leftover" output.
Electrolyzer 1 1 Yes Yes Yes 1,400W From input H2O, output mixed H2 and O2.
Active Vent 1 pipe, 1 space Yes, reversable Yes Yes 100W Pump pressure between a space and a pipe.
Passive Vent 1 pipe, 1 space No No No - Equalize pressure between a space and a pipe.
Wall Cooler x x 1w switch comp 100W function
Air Conditioner x x 1w switch comp 100W function
Gas Tank Storage x x 1w switch comp 100W function
Tank (Large and Small) x x 1w switch comp 100W function
Tank Connector x x 1w switch comp 100W function

One-way: Does the component prevent gas from flowing the wrong way, from output to input?

Switched: Does it prevent all gas flow when switched off or unpowered?

Compressor: Will it actively increase pressure in the output and decrease pressure in the input? If no, the component only allows pressure to change toward equilibrium between input and output.

Note 1: While the Pipe Gas Mixer will actively compress from output to input, it will stop when either input is empty, to preserve the mix ratio.