Difference between revisions of "Atmospheric Components Quick Reference"
From Unofficial Stationeers Wiki
TheNicestGuy (talk | contribs) (Add pump.) |
TheNicestGuy (talk | contribs) (Add mixer and filter.) |
||
Line 16: | Line 16: | ||
|- | |- | ||
| [[Pressure_Regulator#Back_Pressure_Regulator|Back Pressure Regulator]] || 1 || 1 || Yes || Yes || Yes || 100W || Achieve target pressure at input. | | [[Pressure_Regulator#Back_Pressure_Regulator|Back Pressure Regulator]] || 1 || 1 || Yes || Yes || Yes || 100W || Achieve target pressure at input. | ||
+ | |- | ||
+ | | [[Pipe Gas Mixer]] || 2 || 1 || Yes || Yes || Yes<sup>1</sup> || 100W || Combine two input mixes into one output mix, at an adjustable ratio. | ||
+ | |- | ||
+ | | [[Kit (Atmospherics) Filtration|Filtration]] || 1 || 2 || Yes || Yes || Yes || 5W || Separate an input mix into a pure output and a "leftover" output. | ||
|- | |- | ||
| [[Active Vent]] || colspan="2"|1 pipe, 1 space || Yes, reversable || Yes || Yes || 100W || Pump pressure between a space and a pipe. | | [[Active Vent]] || colspan="2"|1 pipe, 1 space || Yes, reversable || Yes || Yes || 100W || Pump pressure between a space and a pipe. | ||
|- | |- | ||
| [[Passive Vent]] || colspan="2"|1 pipe, 1 space || No || No || No || - || Equalize pressure between a space and a pipe. | | [[Passive Vent]] || colspan="2"|1 pipe, 1 space || No || No || No || - || Equalize pressure between a space and a pipe. | ||
− | |||
− | |||
|- | |- | ||
| [[Wall Cooler]] || x || x || 1w || switch || comp || 100W || function | | [[Wall Cooler]] || x || x || 1w || switch || comp || 100W || function | ||
Line 28: | Line 30: | ||
|- | |- | ||
| [[Kit (Atmospherics) Electrolyzer|Electrolyzer]] || x || x || 1w || switch || comp || 100W || function | | [[Kit (Atmospherics) Electrolyzer|Electrolyzer]] || x || x || 1w || switch || comp || 100W || function | ||
− | |||
− | |||
|- | |- | ||
| [[Gas Tank Storage]] || x || x || 1w || switch || comp || 100W || function | | [[Gas Tank Storage]] || x || x || 1w || switch || comp || 100W || function | ||
Line 43: | Line 43: | ||
'''Compressor''': Will it actively increase pressure in the output and decrease pressure in the input? If no, the component only allows pressure to change toward equilibrium between input and output. | '''Compressor''': Will it actively increase pressure in the output and decrease pressure in the input? If no, the component only allows pressure to change toward equilibrium between input and output. | ||
+ | |||
+ | '''Note 1:''' While the Pipe Gas Mixer will actively compress from output to input, it will stop when either input is empty, to preserve the mix ratio. |
Revision as of 09:27, 26 May 2020
This is a quick reference to the traits of the various components of a piped-fluid network.
Component | Inputs | Outputs | One-way? | Switched? | Compressor? | Max. Power | Primary Function |
---|---|---|---|---|---|---|---|
Pipe (various shapes) | 2-6 generic | No | No | No | - | Provide a pathway. | |
Pipe Valve | 2 generic | No | Manual | No | - | Open/close flow manually. | |
Pipe Digital Valve | 2 generic | No | Yes | No | 25W | Open/close flow using logic circuits. | |
Pipe Volume Pump | 1 | 1 | Yes | Yes | Yes | 800W, varies | Pump fluid at adjustable rate. |
Pressure Regulator | 1 | 1 | Yes | Yes | Yes | 100W | Achieve target pressure at output. |
Back Pressure Regulator | 1 | 1 | Yes | Yes | Yes | 100W | Achieve target pressure at input. |
Pipe Gas Mixer | 2 | 1 | Yes | Yes | Yes1 | 100W | Combine two input mixes into one output mix, at an adjustable ratio. |
Filtration | 1 | 2 | Yes | Yes | Yes | 5W | Separate an input mix into a pure output and a "leftover" output. |
Active Vent | 1 pipe, 1 space | Yes, reversable | Yes | Yes | 100W | Pump pressure between a space and a pipe. | |
Passive Vent | 1 pipe, 1 space | No | No | No | - | Equalize pressure between a space and a pipe. | |
Wall Cooler | x | x | 1w | switch | comp | 100W | function |
Air Conditioner | x | x | 1w | switch | comp | 100W | function |
Electrolyzer | x | x | 1w | switch | comp | 100W | function |
Gas Tank Storage | x | x | 1w | switch | comp | 100W | function |
Tank (Large and Small) | x | x | 1w | switch | comp | 100W | function |
Tank Connector | x | x | 1w | switch | comp | 100W | function |
One-way: Does the component prevent gas from flowing the wrong way, from output to input?
Switched: Does it prevent all gas flow when switched off or unpowered?
Compressor: Will it actively increase pressure in the output and decrease pressure in the input? If no, the component only allows pressure to change toward equilibrium between input and output.
Note 1: While the Pipe Gas Mixer will actively compress from output to input, it will stop when either input is empty, to preserve the mix ratio.