Actions

Difference between revisions of "Pipe Volume Pump"

From Unofficial Stationeers Wiki

(fix wrong power req)
(Added a image for the volume pump)
Line 13: Line 13:
 
| recipe_machine1 = Hydraulic Pipe Bender
 
| recipe_machine1 = Hydraulic Pipe Bender
 
| recipe_cost1 = 5g [[Iron]], 2g [[Gold]], 3g [[Copper]]
 
| recipe_cost1 = 5g [[Iron]], 2g [[Gold]], 3g [[Copper]]
| constructs = [[Volume Pump]]
+
| constructs = [[Volume Pump|Pipe_Volume_Pump]]
 
}}
 
}}
 
{{Structurebox
 
{{Structurebox
 
| name = Volume Pump
 
| name = Volume Pump
| image = [[File:StructureVolumePump.png]]
+
| image = [[File:ItemPipeVolumePump.png]]
 
| prefab_hash = -321403609
 
| prefab_hash = -321403609
 
| prefab_name = StructureVolumePump
 
| prefab_name = StructureVolumePump

Revision as of 22:59, 6 August 2024

Other languages:
English
Kit (Volume Pump)
ItemPipeVolumePump.png
Constructing Options Pipe_Volume_Pump
Properties
Stacks Yes (5)
Recipes
Hydraulic Pipe Bender 5g Iron, 2g Gold, 3g Copper
Logic
Item Hash -1766301997
Item Name ItemPipeVolumePump
Logic Classes
SlotClass.None
SortingClass.Kits
Volume Pump
ItemPipeVolumePump.png
Operation
Power Usage Setting * 20W
Prefab Hash -321403609
Prefab Name StructureVolumePump
Construction
Placed with Kit (Volume Pump)
Placed on Small Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Volume Pump)



The volume pump pumps pumpable gases. It also separates out pipe networks into separate networks.
- Stationpedia

Description

Used to pump gasses throughout a pipe, featuring an adjustable valve 0-10 Liters and requiring power (20W per Liter). All the gasses in the pipes behind it will be completely pushed in front of it when powered, and blocks any flow of gasses in either direction when unpowered.

Note that valve settings are for the rate at which the pump operates, in volume per tick (0.5 seconds).

To calculate the moles per tick, use the following equation: n = (P * V) / (R * T)

Where:

  • P = Input pressure
  • V = The volume you set
  • n = Moles per tick
  • R = Gas constant (8.3144)
  • T = Input temperature (in Kelvin)

Data Network Properties

These are all Data Network properties of this device.

Data Parameters

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).

Click here to see/hide all the data network properties
Parameter Name Data Type Access Value Description
Power Boolean
Read
0 Unpowered Can be read to return if the Volume Pump is correctly powered or not, set via the power system, return 1 if powered and 0 if not
1 Powered
Error Boolean
Read
0

1 if device is in error state, otherwise 0
1 Error
Lock Boolean
Read Write
0 Unlocked Disable manual operation of the Volume Pump.
1 Locked
Setting Integer
Read Write
0.0 to 10.0 Sets the flow rate in liters
Maximum Float
Read
Maximum setting of the Volume Pump
Ratio Float
Read
0.0 to 1.0 Setting / Maximum
On Boolean
Read Write
0 Off The current state of the Volume Pump.
1 On
RequiredPower Integer
Read
Idle operating power quantity, does not necessarily include extra demand power
PrefabHash Integer
Read
The hash of the structure
ReferenceId Integer
Read
Unique Reference Identifier for this object
NameHash Integer
Read
Provides the hash value for the name of the object as a 32 bit integer.