Difference between revisions of "Kit (Switch)"
From Unofficial Stationeers Wiki
m (moved boxes up the page) |
|||
Line 70: | Line 70: | ||
| Lock || Boolean || Gets the current lock state | | Lock || Boolean || Gets the current lock state | ||
|- | |- | ||
− | | Setting || | + | | Setting || Integer || |
|- | |- | ||
| PrefabHash || String || | | PrefabHash || String || | ||
Line 108: | Line 108: | ||
| Activate|| Boolean || Returns 1 if the activate state was just set by a write or IC | | Activate|| Boolean || Returns 1 if the activate state was just set by a write or IC | ||
|- | |- | ||
− | | Setting|| | + | | Setting|| Integer || Gets the current value of the button |
|- | |- | ||
| PrefabHash || String || | | PrefabHash || String || | ||
Line 128: | Line 128: | ||
| Mode || Boolean || Sets the maximum value you can set when using the dial | | Mode || Boolean || Sets the maximum value you can set when using the dial | ||
|- | |- | ||
− | | Setting || | + | | Setting || Integer || Sets the current value of the dial |
|- | |- | ||
|} | |} | ||
Line 139: | Line 139: | ||
| Mode || Boolean || Gets the maximum value you can set when using the dial | | Mode || Boolean || Gets the maximum value you can set when using the dial | ||
|- | |- | ||
− | | Setting || | + | | Setting || Integer || Get the current value of the dial |
|- | |- | ||
| PrefabHash || String || | | PrefabHash || String || |
Revision as of 20:55, 23 June 2022
Recipe | |
---|---|
Created With | Electronics Printer, Fabricator |
Cost | 1g Gold, 1g Copper |
Operation | |
---|---|
Power Usage | 0W |
Prefab Hash | 321604921 |
Construction | |
Placed with | Kit (Logic Switch) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Logic Switch) |
Operation | |
---|---|
Power Usage | 0W |
Prefab Hash | 1220484876 |
Construction | |
Placed with | Kit (Logic Switch) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Logic Switch) |
Operation | |
---|---|
Power Usage | 0W |
Prefab Hash | 491845673 |
Construction | |
Placed with | Kit (Logic Switch) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Logic Switch) |
Operation | |
---|---|
Power Usage | 0W |
Prefab Hash | 554524804 |
Construction | |
Placed with | Kit (Logic Switch) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Logic Switch) |
Contents
Data Network Properties
These are all Data Network properties of this device.
Switch
The Logic Switch gives players the ability to add controls to control circuits without requiring tools. Toggles output value between 0 and 1.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Lock | Boolean | Prevents using the switch when set to 1 (not working as of v0.2.2891.14453) |
Open | Boolean | Set the current switch state |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Lock | Boolean | Gets the current lock state |
Setting | Integer | |
PrefabHash | String | |
Open | Boolean | Gets the current state |
Connectors
- Top: Data Output
- Bottom: Data Output
Lever
Toggles output value between 0 and 1.
Connectors
- Top: Data Output
- Bottom: Data Output
Button
Sends a pulse of 0.5 seconds long of value 1.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Activate | Boolean | Sets the button setting to 1 |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Activate | Boolean | Returns 1 if the activate state was just set by a write or IC |
Setting | Integer | Gets the current value of the button |
PrefabHash | String |
Connectors
- Top: Data Output
- Bottom: Data Output
Dial
Allows user to select a value between 0 and the maximum set by use of screws.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Mode | Boolean | Sets the maximum value you can set when using the dial |
Setting | Integer | Sets the current value of the dial |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Mode | Boolean | Gets the maximum value you can set when using the dial |
Setting | Integer | Get the current value of the dial |
PrefabHash | String | |
Ratio | Integer |
Connectors
- Bottom: Data Output
Screws
- Bottom Left: Decrease maximum possible value to be set by dial.
- Bottom Right: Increase maximum possible value to be set by dial.