Actions

Difference between revisions of "Kit (Switch)"

From Unofficial Stationeers Wiki

(Removed the global boxes for "Data Parameters" and "Data Outputs" and added both boxes for every logic switch type. Changes parameters and outputs to match the ingame documentation. Added descriptions.)
(Fixed some stuf.)
Line 53: Line 53:
 
! Parameter Name !! Data Type !! Description
 
! Parameter Name !! Data Type !! Description
 
|-
 
|-
| Lock || Boolean || Prevents using the switch when set to 1
+
| Lock || Boolean || Prevents using the switch when set to 1 (not working as of v0.2.2891.14453)
 
|-
 
|-
 
| Open || Boolean || Set the current switch state
 
| Open || Boolean || Set the current switch state
Line 86: Line 86:
  
 
= Button =
 
= Button =
Sends a pulse of 0.5(i think) seconds long of value 1.
+
Sends a pulse of 0.5 seconds long of value 1.
  
 
{{Data Parameters}}
 
{{Data Parameters}}

Revision as of 07:42, 13 July 2021

Data Network Properties

These are all Data Network properties of this device.


Kit (Switch)
Recipe
Created With Electronics Printer, Fabricator
Cost 1g Gold, 1g Copper
Switch
Switch.jpg
Construction
Placed with Kit (Logic Switch)
Placed on Small Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Logic Switch)
Lever
Lever.jpg
Construction
Placed with Kit (Logic Switch)
Placed on Small Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Logic Switch)
Button
Button.jpg
Construction
Placed with Kit (Logic Switch)
Placed on Small Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Logic Switch)
Dial
Dial.jpg
Construction
Placed with Kit (Logic Switch)
Placed on Small Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Logic Switch)


Switch

The Logic Switch gives players the ability to add controls to control circuits without requiring tools. Toggles output value between 0 and 1.

Data Parameters

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).


Parameter Name Data Type Description
Lock Boolean Prevents using the switch when set to 1 (not working as of v0.2.2891.14453)
Open Boolean Set the current switch state

Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Lock Boolean Gets the current lock state
Setting Boolean
PrefabHash String
Open Boolean Gets the current state

Connectors

  • Top: Data Output
  • Bottom: Data Output

Lever

Toggles output value between 0 and 1.

Connectors

  • Top: Data Output
  • Bottom: Data Output

Button

Sends a pulse of 0.5 seconds long of value 1.

Data Parameters

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).


Parameter Name Data Type Description
Activate Boolean Sets the button setting to 1

Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Activate Boolean Returns 1 if the activate state was just set by a write or IC
Setting Boolean Gets the current value of the button
PrefabHash String

Connectors

  • Top: Data Output
  • Bottom: Data Output

Dial

Allows user to select a value between 0 and the maximum set by use of screws.

Data Parameters

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).


Parameter Name Data Type Description
Mode Boolean Sets the maximum value you can set when using the dial
Setting Boolean Sets the current value of the dial

Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Mode Boolean Gets the maximum value you can set when using the dial
Setting Boolean Get the current value of the dial
PrefabHash String
Ratio Integer

Connectors

  • Bottom: Data Output

Screws

  • Bottom Left: Decrease maximum possible value to be set by dial.
  • Bottom Right: Increase maximum possible value to be set by dial.