Actions

Difference between revisions of "Basic Chutes"

From Unofficial Stationeers Wiki

(update itembox)
(Chute Bin: removed info on chute bin, moving to powered chutes page)
 
(One intermediate revision by one other user not shown)
Line 43: Line 43:
 
|{{Recipe/row |machine = Recycler |mats = 1,5g [[Iron]] |time = 5 |energy = 1000}}
 
|{{Recipe/row |machine = Recycler |mats = 1,5g [[Iron]] |time = 5 |energy = 1000}}
 
}}
 
}}
 
= Chute Bin =
 
 
{{Data Network Header}}
 
 
{{Data Parameters}}
 
{| class="wikitable"
 
|-
 
! Parameter Name !! Data Type !! Description
 
|-
 
| Open || Boolean || Opens the Chute Bin, when set to 1. Closes it, when set to 0.
 
|-
 
| On || Boolean || Turns the Chute Bin on when set to 1. Turns it off, when set to 0.
 
|-
 
| Lock || Boolean || Prevents the player from pulling the lever on the Chute Bin. 1 = Locked, 0 = Unlocked.
 
|}
 
 
{{Data Outputs}}
 
{| class="wikitable"
 
|-
 
! Output Name !! Data Type !! Description
 
|-
 
| Power || Boolean || Returns whether the Chute Bin is turned on and receives power. (0 for no, 1 for yes)
 
|-
 
| Open || Boolean || Returns whether the Chute Bin is open. (0 for no, 1 for yes)
 
|-
 
| Error || Boolean || Returns whether the Chute Bin is flashing an error. (0 for no, 1 for yes)
 
|-
 
| On || Boolean || Returns whether the Chute Bin is turned on. (0 for no, 1 for yes)
 
|-
 
| RequiredPower || Integer || Returns the current amount of power, required by the Chute Bin, in watts.
 
|}
 
  
 
= Chute Outlet =
 
= Chute Outlet =
  
 
{{Data Network Header}}
 
{{Data Network Header}}
 
+
{{Data Parameters|
{{Data Parameters}}
+
{{Data Parameters/row|Lock|Boolean|Disable manual operation of the Chute Outlet.|multiple=2|0|Unlocked|1|Locked}}
{| class="wikitable"
+
{{Data Parameters/row|ClearMemory|Integer|r=0|When set to 1, clears the counter memory (e.g. ExportCount). Will set itself back to 0 when actioned}}
|-
+
{{Data Parameters/row|ExportCount|Integer|w=0|How many items exported since last ClearMemory}}
! Parameter Name !! Data Type !! Description
+
{{Data Parameters/row|ImportCount|Integer|w=0|How many items imported since last ClearMemory}}
|-
+
{{Data Parameters/row|PrefabHash|Integer|w=0|The hash of the structure}}
| Open || Boolean || Opens the Chute Outlet when set to 1.
+
{{Data Parameters/row|ReferenceId|Integer|w=0|Unique Reference Identifier for this object}}
|-
+
{{Data Parameters/row|NameHash|Integer|w=0|Provides the hash value for the name of the object as a 32 bit integer.}}
| Lock || Boolean || Locks the Chute Outlet when set to 1. Unlocks it, when set to 0.
+
}}
|}
 
 
 
{{Data Outputs}}
 
{| class="wikitable"
 
|-
 
! Output Name !! Data Type !! Description
 
|-
 
| Open || Boolean || Returns whether the Chute Outlet is open. (0 for no, 1 for yes) This only returns 1 briefly, when the Chute Outlet opens.
 
|-
 
| Lock || Boolean || Returns whether the Chute Outlet is locked. (0 for no, 1 for yes)
 
|-
 
| ImportQuantity || Integer || Returns the number of items, the Chute Outlet is holding, in grams.
 
|-
 
| ImportSlotOccupant || Boolean || Returns whether the Chute Outlet is holding an item. (0 for no, 1 for yes)
 
|}
 
  
 
= Chute Inlet =
 
= Chute Inlet =
  
 
{{Data Network Header}}
 
{{Data Network Header}}
 
+
{{Data Parameters|
{{Data Parameters|empty}}
+
{{Data Parameters/row|Lock|Boolean|Disable manual operation of the Chute Inlet.|multiple=2|0|Unlocked|1|Locked}}
 
+
{{Data Parameters/row|ClearMemory|Integer|r=0|When set to 1, clears the counter memory (e.g. ExportCount). Will set itself back to 0 when actioned}}
{{Data Outputs}}
+
{{Data Parameters/row|ImportCount|Integer|w=0|How many items imported since last ClearMemory}}
{| class="wikitable"
+
{{Data Parameters/row|PrefabHash|Integer|w=0|The hash of the structure}}
|-
+
{{Data Parameters/row|ReferenceId|Integer|w=0|Unique Reference Identifier for this object}}
! Output Name !! Data Type !! Description
+
{{Data Parameters/row|NameHash|Integer|w=0|Provides the hash value for the name of the object as a 32 bit integer.}}
|-
+
}}
| Lock || Boolean || 1 if the inlet is locked, 0 if it is not. 
 
|-
 
| ImportCount || Integer || Returns the number of stacks imported by the inlet.
 
|-
 
| PrefabHash || Integer || Returns a hash. (Chute Inlet ItemID?)
 
|}
 

Latest revision as of 15:45, 19 July 2024


Kit (Basic Chutes)
ItemKitChute.png
Constructing Options Chute (Straight), Chute (Corner), Chute (Window), Chute (Junction), Chute Flip Flop Splitter, Chute Valve, Chute Overflow, Chute Inlet, Chute Outlet
Properties
Stacks Yes (10)
Recipes
Autolathe 3g Iron
Hydraulic Pipe Bender 3g Iron
Logic
Item Hash 1025254665
Item Name ItemKitChute
Logic Classes
SlotClass.None
SortingClass.Kits
Chute
Construction
Placed with Kit (Chutes)
Placed on Small Grid
Stage 1
Deconstruction
Deconstructed with Wrench
Item received Kit (Chutes)


Chute[edit]

Description[edit]

Used to transport items. The Kit can be used to create 9 different variants, some of them are able to connect to power and logic network.

  • Straight chute: transports items on a straight line
  • Window chute: transports items on a straight line, and the items are visible inside the chute
  • Corner chute: transports items on a perpendicular line
  • Junction (consumes two kits): transports items on a straight and perpendicular line (merges two lines into one)
  • Flip flop Splitter: alternates between transporting an item on a straight and perpendicular line (splits one line in two)
  • Chute Valve: transports items on a straight line. Can be open and closed
  • Chute overflow: transports items on a straight and perpendicular line, where priority is given to the straight line (similar to a flip flop, but instead of 50%, it only goes perpendicular if straight is full)
  • Chute inlet: items can be dropped on it and will transport them on a perpendicular line
  • Chute outlet: items are dropped from the chute to the floor

Recipes[edit]

Manufactory Materials Time Energy
Autolathe 3g Iron 5 500
Hydraulic Pipe Bender 3g Iron 5 500
Recycler 1,5g Iron 5 1000

Chute Outlet[edit]

Data Network Properties[edit]

These are all Data Network properties of this device.

Data Parameters[edit]

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).

Click here to see/hide all the data network properties
Parameter Name Data Type Access Value Description
Lock Boolean
Read Write
0 Unlocked Disable manual operation of the Chute Outlet.
1 Locked
ClearMemory Integer
Write
When set to 1, clears the counter memory (e.g. ExportCount). Will set itself back to 0 when actioned
ExportCount Integer
Read
How many items exported since last ClearMemory
ImportCount Integer
Read
How many items imported since last ClearMemory
PrefabHash Integer
Read
The hash of the structure
ReferenceId Integer
Read
Unique Reference Identifier for this object
NameHash Integer
Read
Provides the hash value for the name of the object as a 32 bit integer.


Chute Inlet[edit]

Data Network Properties[edit]

These are all Data Network properties of this device.

Data Parameters[edit]

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).

Click here to see/hide all the data network properties
Parameter Name Data Type Access Value Description
Lock Boolean
Read Write
0 Unlocked Disable manual operation of the Chute Inlet.
1 Locked
ClearMemory Integer
Write
When set to 1, clears the counter memory (e.g. ExportCount). Will set itself back to 0 when actioned
ImportCount Integer
Read
How many items imported since last ClearMemory
PrefabHash Integer
Read
The hash of the structure
ReferenceId Integer
Read
Unique Reference Identifier for this object
NameHash Integer
Read
Provides the hash value for the name of the object as a 32 bit integer.