Difference between revisions of "Tank"
From Unofficial Stationeers Wiki
(added cross references) |
(Clarified Max Capacity) |
||
Line 13: | Line 13: | ||
== Description == <!--T:2--> | == Description == <!--T:2--> | ||
− | [[Tank]]s are used to store large amounts gasses. 50000L is currently the largest capacity container for gasses. Combined with its high bursting pressure (>300 atmospheres) it can store upwards of 72000 mols at room temperature (20 °C). | + | [[Tank]]s are used to store large amounts gasses. 50000L (Large Tank) is currently the largest capacity container for gasses. Combined with its high bursting pressure (>300 atmospheres) it can store upwards of 72000 mols at room temperature (20 °C). |
Given that [[pipes]] will burst at pressures greater than 60,795KPa, this is also a limit for the tanks, as all gases will be lost if the pipe connected to a tank ruptures. | Given that [[pipes]] will burst at pressures greater than 60,795KPa, this is also a limit for the tanks, as all gases will be lost if the pipe connected to a tank ruptures. |
Revision as of 22:26, 24 December 2020
Max Pressure | >30,000 kPa? |
---|---|
Recipe | |
Created With | Hydraulic Pipe Bender, Fabricator |
Cost | 5g copper + 20g steel |
Description
Tanks are used to store large amounts gasses. 50000L (Large Tank) is currently the largest capacity container for gasses. Combined with its high bursting pressure (>300 atmospheres) it can store upwards of 72000 mols at room temperature (20 °C).
Given that pipes will burst at pressures greater than 60,795KPa, this is also a limit for the tanks, as all gases will be lost if the pipe connected to a tank ruptures.
Small Tank
1 Kit to place volume 6000L | |
Construction | |
---|---|
Placed with | Kit (Tank) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Tank) |
Data Network Properties
These are all Data Network properties of this device.
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Maximum | ||
Temperature | ||
Setting | ||
RatioWater | ||
RatioVolatiles | ||
RatioPollutant | ||
RatioOxygen | ||
RatioNitrousOxide | ||
RatioNitrogen | ||
RatioCarbonDioxide | ||
Ratio | ||
Quantity | ||
Pressure | ||
PrefabHash | ||
Open |
Large Tank
File:TankBig.png | |
5 Kits to place volume 50000L | |
Construction | |
---|---|
Placed with | Kit (Tank) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Tank) |