Difference between revisions of "Pipes"
From Unofficial Stationeers Wiki
(added mpa (60)) |
(corrected mpa to MPa (SI units)) |
||
Line 24: | Line 24: | ||
<!--T:3--> | <!--T:3--> | ||
* Pipes can store some gas inside of them, which can be used with small airlocks to store gas when depressurizing | * Pipes can store some gas inside of them, which can be used with small airlocks to store gas when depressurizing | ||
− | * Pipes will burst if the pressure differential between the inside pressure and outside atmosphere is greater than 60,795KPa ( | + | * Pipes will burst if the pressure differential between the inside pressure and outside atmosphere is greater than 60,795KPa (60MPa) (plus a random check to allow for short bursts over this limit) |
* A contiguous pipe (not interrupted by valves, regulators, pumps etc.) of any length, will always have the same pressure, temperature and mixture over its entire length. No matter at what point of the pipe you're introducing new gases into the pipe, they will instantly and evenly "average out" over the entire pipe. | * A contiguous pipe (not interrupted by valves, regulators, pumps etc.) of any length, will always have the same pressure, temperature and mixture over its entire length. No matter at what point of the pipe you're introducing new gases into the pipe, they will instantly and evenly "average out" over the entire pipe. | ||
</translate> | </translate> |
Revision as of 10:41, 25 May 2020
Volume | 100L |
---|---|
Properties | |
Stacks | Yes, 20 |
Recipe | |
Created With | Hydraulic Pipe Bender, Fabricator |
Cost | 0.5g Iron |
Construction | |
---|---|
Placed with | Kit (Pipe) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Wrench |
Item received | Kit (Pipe) |
Pipes are used to transport gas. Pipes are one of the possible types of inputs/outputs from a structure (the others being Cables and Chutes).
Tips
- Pipes can store some gas inside of them, which can be used with small airlocks to store gas when depressurizing
- Pipes will burst if the pressure differential between the inside pressure and outside atmosphere is greater than 60,795KPa (60MPa) (plus a random check to allow for short bursts over this limit)
- A contiguous pipe (not interrupted by valves, regulators, pumps etc.) of any length, will always have the same pressure, temperature and mixture over its entire length. No matter at what point of the pipe you're introducing new gases into the pipe, they will instantly and evenly "average out" over the entire pipe.