Difference between revisions of "Active Vent"
From Unofficial Stationeers Wiki
(informations on the built-in pressure sensor and the pressure external parameter) |
(Added note about Inward mode + ExternalPressure) |
||
Line 52: | Line 52: | ||
| Mode || Integer || Sets the Active Vent mode to the passed setting. (See [[#Mode_Values|Mode Values]]) | | Mode || Integer || Sets the Active Vent mode to the passed setting. (See [[#Mode_Values|Mode Values]]) | ||
|- | |- | ||
− | | PressureExternal || Float || Sets the desired external pressure (Will be overwritten by a mode switch) | + | | PressureExternal || Float || Sets the desired external pressure (Will be overwritten by a mode switch. NOTE: Setting this on a vent that is running in "Inward" mode seems to close the vent while it's running, causing it to move no gas) |
|- | |- | ||
| PressureInternal || Float || Does not function. | | PressureInternal || Float || Does not function. |
Revision as of 11:40, 5 January 2020
Properties | |
---|---|
Stacks | Yes (5) |
Recipe | |
Created With | Hydraulic Pipe Bender, Fabricator |
Cost | 5g Iron, 1g Gold, 5g Copper |
Operation | |
---|---|
Power Usage | 100W |
Construction | |
Placed with | Active Vent (Item) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Active Vent (Item) |
Contents
Description
Used to move gasses from pipes, by using its inward or outward switches. It needs to be powered to function.
Active vents have a build-in pressure sensor and will use it to try to set the external pressure to the value of the "PressureExternal" parameter.
This parameter is set to its default values everytime the mode switch is used. Default values are 101kPa for Outward and 0kPa for Inward.
Note: The insert slot currently takes any item and seems to have no effect.
Data Network Properties
These are all Data Network properties of this device.
Mode Values
These lists the values and meanings for the "Mode" property of the Active Vent.
Value | Meaning |
---|---|
0 | "Outward" mode (Pumping gas from the connected pipe network to the outside.) |
1 | "Inward" mode (Pumping gas from the outside to the connected pipe network.) |
2 | (Unknown) |
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Open | Boolean | Does not function. |
Mode | Integer | Sets the Active Vent mode to the passed setting. (See Mode Values) |
PressureExternal | Float | Sets the desired external pressure (Will be overwritten by a mode switch. NOTE: Setting this on a vent that is running in "Inward" mode seems to close the vent while it's running, causing it to move no gas) |
PressureInternal | Float | Does not function. |
Lock | Boolean | Locks the Active Vent, when set to 1. Unlocks it, when set to 0. |
Setting | Float | Does not function. |
On | Boolean | Turns the Active Vent on, when set to 1. Turns it off, when set to 0. |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Active Vent is receiving power and is turned on. (0 for no, 1 for yes) |
Open | Boolean | Returns whether the Active Vent is open. (0 for no, 1 for yes) (Untested) |
Mode | Integer | Returns the setting of the current mode of the Active Vent. (See Mode Values) |
Error | Boolean | Returns whether the Active Vent is currently flashing an error. (0 for no, 1 for yes) |
PressureExternal | Float | Returns the desired external pressure of the Active Vent. |
PressureInternal | Float | Returns the desired internal pressure of the Active vent. (Untested) |
Lock | Boolean | Returns whether the Active Vent is locked. (0 for no, 1 for yes) |
Setting | Float | Returns a range from 0.0 to 100.0. (Assumption) Returns the percentage amount of pumping throughput of the Active Vent. |
Maximum | Integer | Returns 100. (Assumption) Returns the maximum throughput percentage of the Active Vent. |
Ratio | Float | Returns a range from 0.0 to 1.0. (Assumption) Returns the percentage amount of pumping throughput of the Active Vent. |
On | Boolean | Returns whether the Active Vent is set to on. (0 for no, 1 for yes) |
RequiredPower | Integer | Returns the current amount of power needed for the Active Vent. |