Difference between revisions of "Airlock (Structure)"
From Unofficial Stationeers Wiki
Ipottinger (talk | contribs) m (Add missing Settings section) |
(Updated data outputs with 'mode') |
||
Line 80: | Line 80: | ||
|- | |- | ||
| RequiredPower || Integer || Returns the current watts of power required by the Airlock. | | RequiredPower || Integer || Returns the current watts of power required by the Airlock. | ||
+ | |- | ||
+ | | Mode || Boolean || Holds intended value for Open. Opening process is not instant so this value can be used to detect attempt to open airlock. | ||
|} | |} | ||
Revision as of 16:57, 12 June 2019
Operation | |
---|---|
Power Usage | 25W |
Construction | |
Placed with | Kit (Airlock) |
Placed on | Large Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Airlock) |
Contents
Purpose
An Airlock is a powered Portal suitable for use in constructing an airlock chamber. Guide (Airlock) provides additional information regarding the function, construction, and operation of airlocks.
Characteristics
- It can withstand a Pressure differential of 1MPA.
- It consumes 25W of Power per Tick.
- It has a separate Power Port and Data Port.
- It has a keypad on both sides.
- It has indicator lights.
- If unlocked, it can be manually operated using a Crowbar regardless of its power state.
- If enslaved by a regular or a advanced airlock circuit, it cannot be operated manually.
User Interface
An Airlock provides the following user interface:
Name | Type | Function |
---|---|---|
Keypad | Keypad | Opens or closes the door as long as it has power |
Lock | Indicator | Turns red when locked and green when unlocked |
Settings
An Airlock has no settings.
Construction
An Airlock is constructed using 1 x Kit (Airlock).
Deconstruction
An Airlock can be deconstructed at any time using a Hand Drill.
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Open | Boolean | Opens the Airlock when set to 1. Closes it when set to 0. |
Lock | Boolean | Locks the Airlock when set to 1. Unlocks it when set to 0. |
On | Boolean | Turns the Airlock on when set to 1. Turns the Airlock off when set to 0. |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Airlock is turned on and receiving power. (0 for no, 1 for yes) |
Open | Boolean | Returns whether the Airlock is open. (0 for no, 1 for yes) |
Lock | Boolean | Returns whether the Airlock is locked. (0 for no, 1 for yes) |
On | Boolean | Returns whether the Airlock is turned on. (0 for no, 1 for yes) |
RequiredPower | Integer | Returns the current watts of power required by the Airlock. |
Mode | Boolean | Holds intended value for Open. Opening process is not instant so this value can be used to detect attempt to open airlock. |