Actions

Difference between revisions of "Airlock (Structure)"

From Unofficial Stationeers Wiki

m (correct links)
m (section for translation)
Line 11: Line 11:
 
  | item_rec1        = [[Kit (Airlock)]]
 
  | item_rec1        = [[Kit (Airlock)]]
 
}}
 
}}
 +
<!--T:1-->
 
==Description==
 
==Description==
An Airlock is a powered door suitable for use in constructing an [[Guide (Airlock)|airlock chamber]]. It can withstand a [[Pressure|pressure]] differential of 1MPA and consumes 25W of [[Special:MyLanguage/Energy|energy]] per [[Special:MyLanguage/Energy#Tick|tick]].
+
An Airlock is a powered [[Portal]] suitable for use in constructing an [[Guide (Airlock)|airlock chamber]]. It can withstand a [[Pressure]] differential of 1MPA and consumes 25W of [[Power]] per [[Tick]].
  
An Airlock has separate [[Power#Ports|power]] and [[Data#Ports|data]] ports, a keypad on both sides which when clicked will open or close the door as long as it has power. An Airlock also has indicator lights which will turn red if the door is locked and green if the door is unlocked. As long as the door is unlocked it can be manually operated using a [[Crowbar|crowbar]] regardless of its power state.
+
An Airlock has separate [[Power Port]] and [[Data Port]], a keypad on both sides which when clicked will open or close the door as long as it has power. An Airlock also has indicator lights which will turn red if the door is locked and green if the door is unlocked. As long as the door is unlocked, it can be manually operated using a [[Crowbar|crowbar]] regardless of its power state.
  
 
When an Airlock is enslaved by a [[Circuitboard (Airlock)|regular]] or a [[Circuitboard (Advanced Airlock)|advanced]] airlock circuit, it cannot be opened or closed manually, which could be a problem when power is lost.
 
When an Airlock is enslaved by a [[Circuitboard (Airlock)|regular]] or a [[Circuitboard (Advanced Airlock)|advanced]] airlock circuit, it cannot be opened or closed manually, which could be a problem when power is lost.
  
 +
<!--T:2-->
 
==Construction==
 
==Construction==
 
An Airlock is constructed using 1 x [[Kit (Airlock)]].
 
An Airlock is constructed using 1 x [[Kit (Airlock)]].
  
 +
<!--T:3-->
 
==Deconstruction==
 
==Deconstruction==
 
An Airlock can be deconstructed at any time using a [[Hand Drill]].
 
An Airlock can be deconstructed at any time using a [[Hand Drill]].
Line 27: Line 30:
  
 
{{Data Parameters}}
 
{{Data Parameters}}
 +
<!--T:4-->
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
Line 39: Line 43:
  
 
{{Data Outputs}}
 
{{Data Outputs}}
 +
<!--T:5-->
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
Line 54: Line 59:
 
|}
 
|}
  
 +
<!--T:6-->
 
==See Also==
 
==See Also==
 
* [[Guide (Airlock)]]
 
* [[Guide (Airlock)]]

Revision as of 05:14, 20 March 2019


Airlock
Operation
Power Usage 25W
Construction
Placed with Kit (Airlock)
Placed on Large Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Airlock)

Description

An Airlock is a powered Portal suitable for use in constructing an airlock chamber. It can withstand a Pressure differential of 1MPA and consumes 25W of Power per Tick.

An Airlock has separate Power Port and Data Port, a keypad on both sides which when clicked will open or close the door as long as it has power. An Airlock also has indicator lights which will turn red if the door is locked and green if the door is unlocked. As long as the door is unlocked, it can be manually operated using a crowbar regardless of its power state.

When an Airlock is enslaved by a regular or a advanced airlock circuit, it cannot be opened or closed manually, which could be a problem when power is lost.

Construction

An Airlock is constructed using 1 x Kit (Airlock).

Deconstruction

An Airlock can be deconstructed at any time using a Hand Drill.

Data Network Properties

These are all Data Network properties of this device.

Data Parameters

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).


Parameter Name Data Type Description
Open Boolean Opens the Airlock when set to 1. Closes it when set to 0.
Lock Boolean Locks the Airlock when set to 1. Unlocks it when set to 0.
On Boolean Turns the Airlock on when set to 1. Turns the Airlock off when set to 0.

Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Power Boolean Returns whether the Airlock is turned on and receiving power. (0 for no, 1 for yes)
Open Boolean Returns whether the Airlock is open. (0 for no, 1 for yes)
Lock Boolean Returns whether the Airlock is locked. (0 for no, 1 for yes)
On Boolean Returns whether the Airlock is turned on. (0 for no, 1 for yes)
RequiredPower Integer Returns the current watts of power required by the Airlock.

See Also