==Description== | ==Description== | ||
− | An Airlock is a powered door suitable for use in constructing an [[ | + | An Airlock is a powered door suitable for use in constructing an [[Guide (Airlock)|airlock chamber]]. It can withstand a [[Pressure|pressure]] differential of 1MPA and consumes 25W of [[Special:MyLanguage/Energy|energy]] per [[Special:MyLanguage/Energy#Tick|tick]]. |
− | An Airlock has separate [[ | + | An Airlock has separate [[Power#Ports|power]] and [[Data#Ports|data]] ports, a keypad on both sides which when clicked will open or close the door as long as it has power. An Airlock also has indicator lights which will turn red if the door is locked and green if the door is unlocked. As long as the door is unlocked it can be manually operated using a [[Crowbar|crowbar]] regardless of its power state. |
− | When an Airlock is enslaved by a [[ | + | When an Airlock is enslaved by a [[Circuitboard (Airlock)|regular]] or a [[Circuitboard (Advanced Airlock Control)|advanced]] airlock circuit, it cannot be opened or closed manually, which could be a problem when power is lost. |
==Construction== | ==Construction== | ||
− | An Airlock is constructed using 1 x [[ | + | An Airlock is constructed using 1 x [[Kit (Airlock)]]. |
==Deconstruction== | ==Deconstruction== | ||
− | An Airlock can be deconstructed at | + | An Airlock can be deconstructed at any time using a [[Hand Drill]]. |
{{Data Network Header}} | {{Data Network Header}} | ||
Line 31: | Line 31: | ||
! Parameter Name !! Data Type !! Description | ! Parameter Name !! Data Type !! Description | ||
|- | |- | ||
− | | Open || Boolean || Opens the Airlock when set to 1. Closes | + | | Open || Boolean || Opens the Airlock when set to 1. Closes it when set to 0. |
|- | |- | ||
| Lock || Boolean || Locks the Airlock when set to 1. Unlocks it when set to 0. | | Lock || Boolean || Locks the Airlock when set to 1. Unlocks it when set to 0. | ||
Line 55: | Line 55: | ||
==See Also== | ==See Also== | ||
− | + | * [[Guide (Airlock)]] | |
− | + | ||
− | + | * [[Circuitboard (Advanced Airlock Control)]] | |
− | + | * [[Circuitboard (Airlock)]] | |
− | + | * [[Kit (Airlock)]] | |
− | |||
− | |||
− | |||
</translate> | </translate> |
Revision as of 01:15, 18 March 2019
Operation | |
---|---|
Power Usage | 25W |
Construction | |
Placed with | Kit (Airlock) |
Placed on | Large Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Airlock) |
Contents
Description
An Airlock is a powered door suitable for use in constructing an airlock chamber. It can withstand a pressure differential of 1MPA and consumes 25W of energy per tick.
An Airlock has separate power and data ports, a keypad on both sides which when clicked will open or close the door as long as it has power. An Airlock also has indicator lights which will turn red if the door is locked and green if the door is unlocked. As long as the door is unlocked it can be manually operated using a crowbar regardless of its power state.
When an Airlock is enslaved by a regular or a advanced airlock circuit, it cannot be opened or closed manually, which could be a problem when power is lost.
Construction
An Airlock is constructed using 1 x Kit (Airlock).
Deconstruction
An Airlock can be deconstructed at any time using a Hand Drill.
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Open | Boolean | Opens the Airlock when set to 1. Closes it when set to 0. |
Lock | Boolean | Locks the Airlock when set to 1. Unlocks it when set to 0. |
On | Boolean | Turns the Airlock on when set to 1. Turns the Airlock off when set to 0. |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Airlock is turned on and receiving power. (0 for no, 1 for yes) |
Open | Boolean | Returns whether the Airlock is open. (0 for no, 1 for yes) |
Lock | Boolean | Returns whether the Airlock is locked. (0 for no, 1 for yes) |
On | Boolean | Returns whether the Airlock is turned on. (0 for no, 1 for yes) |
RequiredPower | Integer | Returns the current watts of power required by the Airlock. |