Difference between revisions of "Glass Door"
From Unofficial Stationeers Wiki
F1r3w4rr10r (talk | contribs) (Fix grid placement) |
F1r3w4rr10r (talk | contribs) (Update to use the new Data Network templates) |
||
Line 1: | Line 1: | ||
− | [[Category:Construction | + | [[Category:Construction]] |
<languages /> | <languages /> | ||
<!--T:1--> | <!--T:1--> | ||
Line 23: | Line 23: | ||
* They are airtight (when closed), and can withstand around 200kPa pressure, which is lower than [[Composite Doors]], which can withstand around 300kPa. <ref>[https://docs.google.com/spreadsheets/d/1QF-nbW7fUMBaZzKwUp9smkQxVwfxMicF7FhgRFf7-Tw/edit#gid=1718464320 Cheat Sheet]</ref> | * They are airtight (when closed), and can withstand around 200kPa pressure, which is lower than [[Composite Doors]], which can withstand around 300kPa. <ref>[https://docs.google.com/spreadsheets/d/1QF-nbW7fUMBaZzKwUp9smkQxVwfxMicF7FhgRFf7-Tw/edit#gid=1718464320 Cheat Sheet]</ref> | ||
− | + | {{Data Network Header}} | |
− | |||
− | + | {{Data Parameters}} | |
− | |||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
Line 39: | Line 37: | ||
|} | |} | ||
− | + | {{Data Outputs}} | |
− | |||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- |
Revision as of 05:49, 8 July 2018
Properties | |
---|---|
Stacks | No |
Operation | |
---|---|
Power Usage | 25W |
Construction | |
Placed with | Kit (Door) |
Placed on | Large Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Door) |
Contents
Description
The Glass Doors are created by using building with a Kit (Door).
- They can be opened and closed from the panel, or from a Console equipped with Circuitboard (Door Control).
- They are airtight (when closed), and can withstand around 200kPa pressure, which is lower than Composite Doors, which can withstand around 300kPa. [1]
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Open | Boolean | Opens the Glass Door, when set >= 1. Closes it, when set to < 1. |
Lock | Boolean | Locks the Glass Door, when set >= 1. Unlocks it, when set to <1. |
On | Boolean | Turns the Glass Door on, when set >= 1. Turns it off, when set to <1. |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Glass Door is turned on and receives power. (0 for no, 1 for yes) |
Open | Boolean | Returns whether the Glass Door is open. (0 for no, 1 for yes) |
Lock | Boolean | Returns whether the Glass Door is locked. (0 for no, 1 for yes) |
On | Boolean | Returns whether the Glass Door is turned on. (0 for no, 1 for yes) |
RequiredPower | Integer | Returns the current amount of power, required by the Glass Door, in watts. |