Actions

Difference between revisions of "Active Vent"

From Unofficial Stationeers Wiki

(Update to use the new Structurebox syntax)
(Update to use the new Data Network templates)
Line 2: Line 2:
 
<translate>
 
<translate>
 
<!--T:1-->
 
<!--T:1-->
[[Category:Atmospherics]][[Category:Data Network]]
+
[[Category:Atmospherics]]
 
{{Itembox
 
{{Itembox
 
  | name        = Active Vent
 
  | name        = Active Vent
Line 24: Line 24:
 
'''Note''': The insert slot currently takes any item and seems to have no effect.
 
'''Note''': The insert slot currently takes any item and seems to have no effect.
  
== Data Network Properties ==
+
{{Data Network Header}}
These are all [[:Category:Data Network|Data Network]] properties of this device.
 
  
 
=== Mode Values ===
 
=== Mode Values ===
Line 40: Line 39:
 
|}
 
|}
  
=== Data Parameters ===
+
{{Data Parameters}}
These are all parameters, that can be written to with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]] or a [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]]. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.
 
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
Line 61: Line 59:
 
|}
 
|}
  
=== Data Outputs ===
+
{{Data Outputs}}
These are all parameters, that can be read with a [[Kit_(Logic_I/O)#Logic_Reader|Logic Reader]]. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
 
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-

Revision as of 04:33, 8 July 2018

Other languages:
English • ‎español
Active Vent
ItemActiveVent.png
Properties
Stacks Yes (5)
Recipe
Created With Hydraulic Pipe Bender, Fabricator
Cost 5g Iron, 1g Gold, 5g Copper
Active Vent
Operation
Power Usage 100W
Construction
Placed with Active Vent (Item)
Placed on Small Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Active Vent (Item)


Description

Used to move gasses from pipes, by using its inward or outward switches. It needs to be powered to function.

Note: The insert slot currently takes any item and seems to have no effect.

Data Network Properties

These are all Data Network properties of this device.

Mode Values

These lists the values and meanings for the "Mode" property of the Active Vent.

Value Meaning
0 "Outward" mode (Pumping gas from the connected pipe network to the outside.)
1 "Inward" mode (Pumping gas from the outside to the connected pipe network.)
2 (Unknown)

Data Parameters

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).


Parameter Name Data Type Description
Open Boolean Opens the Active Vent, when set to 1. Closes it, when set to 0. (Untested)
Mode Integer Sets the Active Vent mode to the passed setting. (See Mode Values)
PressureExternal Float Sets the desired external pressure of the space outside the Active Vent. (Untested)
PressureInternal Float Sets the desired internal pressure of the pipe network, connected to the Active Vent. (Untested)
Lock Boolean Locks the Active Vent, when set to 1. Unlocks it, when set to 0.
Setting Float Takes a range from 0.0 to 100.0. (Assumption) This sets the percentage amount of pumping throughput of the Active Vent.
On Boolean Turns the Active Vent on, when set to 1. Turns it off, when set to 0.

Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Power Boolean Returns whether the Active Vent is receiving power and is turned on. (0 for no, 1 for yes)
Open Boolean Returns whether the Active Vent is open. (0 for no, 1 for yes) (Untested)
Mode Integer Returns the setting of the current mode of the Active Vent. (See Mode Values)
Error Boolean Returns whether the Active Vent is currently flashing an error. (0 for no, 1 for yes)
PressureExternal Float Returns the desired external pressure of the Active Vent. (Untested)
PressureInternal Float Returns the desired internal pressure of the Active vent. (Untested)
Lock Boolean Returns whether the Active Vent is locked. (0 for no, 1 for yes)
Setting Float Returns a range from 0.0 to 100.0. (Assumption) Returns the percentage amount of pumping throughput of the Active Vent.
Maximum Integer Returns 100. (Assumption) Returns the maximum throughput percentage of the Active Vent.
Ratio Float Returns a range from 0.0 to 1.0. (Assumption) Returns the percentage amount of pumping throughput of the Active Vent.
On Boolean Returns whether the Active Vent is set to on. (0 for no, 1 for yes)
RequiredPower Integer Returns the current amount of power needed for the Active Vent.