Difference between revisions of "Glass Door"
From Unofficial Stationeers Wiki
m |
(pressure rating) |
||
| Line 17: | Line 17: | ||
}} | }} | ||
== Description == <!--T:2--> | == Description == <!--T:2--> | ||
| − | The '''Glass Doors''' are created by using building with a [[Kit (Door)]]. They can be opened and closed from the panel, or from a [[Console]] equipped with [[Circuitboard (Door Control)]]. | + | The '''Glass Doors''' are created by using building with a [[Kit (Door)]]. |
| + | * They can be opened and closed from the panel, or from a [[Console]] equipped with [[Circuitboard (Door Control)]]. | ||
| + | * They are airtight (when closed), and can withstand around 200kPa pressure, which is lower than [[Composite Doors]], which can withstand around 300kPa. <ref>[https://docs.google.com/spreadsheets/d/1QF-nbW7fUMBaZzKwUp9smkQxVwfxMicF7FhgRFf7-Tw/edit#gid=1718464320 Cheat Sheet]</ref> | ||
== Data Network Properties == | == Data Network Properties == | ||
Revision as of 15:22, 23 May 2018
| Properties | |
|---|---|
| Stacks | No |
![]() | |
| Operation | |
|---|---|
| Construction | |
| Placed with | {{{placed_with_item}}} |
| Placed on | {{{placed_on_grid}}} |
Description
The Glass Doors are created by using building with a Kit (Door).
- They can be opened and closed from the panel, or from a Console equipped with Circuitboard (Door Control).
- They are airtight (when closed), and can withstand around 200kPa pressure, which is lower than Composite Doors, which can withstand around 300kPa. [1]
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters, that can be written to with a Logic Writer or a Batch Writer. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.
| Parameter Name | Data Type | Description |
|---|---|---|
| Open | Boolean | Opens the Glass Door, when set to 1. Closes it, when set to 0. |
| Lock | Boolean | Locks the Glass Door, when set to 1. Unlocks it, when set to 0. |
| On | Boolean | Turns the Glass Door on, when set to 1. Turns it off, when set to 0. |
Data Outputs
These are all parameters, that can be read with a Logic Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
| Output Name | Data Type | Description |
|---|---|---|
| Power | Boolean | Returns whether the Glass Door is turned on and receives power. (0 for no, 1 for yes) |
| Open | Boolean | Returns whether the Glass Door is open. (0 for no, 1 for yes) |
| Lock | Boolean | Returns whether the Glass Door is locked. (0 for no, 1 for yes) |
| On | Boolean | Returns whether the Glass Door is turned on. (0 for no, 1 for yes) |
| RequiredPower | Integer | Returns the current amount of power, required by the Glass Door, in watts. |

