Difference between revisions of "Active Vent"
From Unofficial Stationeers Wiki
F1r3w4rr10r (talk | contribs) m (Change deconstruct tool link) |
F1r3w4rr10r (talk | contribs) m (Change Logic to Data Network) |
||
Line 2: | Line 2: | ||
<translate> | <translate> | ||
<!--T:1--> | <!--T:1--> | ||
− | [[Category:Atmospherics]] | + | [[Category:Atmospherics]][[Category:Data Network]] |
{{Itembox | {{Itembox | ||
| name = Active Vent | | name = Active Vent | ||
Line 22: | Line 22: | ||
'''Note''': The insert slot currently takes any item and seems to have no effect. | '''Note''': The insert slot currently takes any item and seems to have no effect. | ||
− | == | + | == Data Network Properties == |
− | These are all | + | These are all [[:Category:Data Network|Data Network]] properties of this device. |
=== Mode Values === | === Mode Values === | ||
Line 38: | Line 38: | ||
|} | |} | ||
− | === | + | === Data Parameters === |
These are all parameters, that can be written to with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]] or a [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]]. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them. | These are all parameters, that can be written to with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]] or a [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]]. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them. | ||
{| class="wikitable" | {| class="wikitable" | ||
Line 59: | Line 59: | ||
|} | |} | ||
− | === | + | === Data Outputs === |
These are all parameters, that can be read with a [[Kit_(Logic_I/O)#Logic_Reader|Logic Reader]]. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them. | These are all parameters, that can be read with a [[Kit_(Logic_I/O)#Logic_Reader|Logic Reader]]. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them. | ||
{| class="wikitable" | {| class="wikitable" |
Revision as of 07:12, 8 April 2018
Properties | |
---|---|
Stacks | Yes (5) |
Recipe | |
Created With | Hydraulic Pipe Bender, Fabricator |
Cost | 5g Iron, 1g Gold, 5g Copper |
Construction | |
---|---|
Placed with | {{{placed_with_item}}} |
Placed on | {{{placed_on_grid}}} |
Contents
Description
Used to move gasses from pipes, by using its inward or outward switches. It needs to be powered to function.
Note: The insert slot currently takes any item and seems to have no effect.
Data Network Properties
These are all Data Network properties of this device.
Mode Values
These lists the values and meanings for the "Mode" property of the Active Vent.
Value | Meaning |
---|---|
0 | "Outward" mode (Pumping gas from the connected pipe network to the outside.) |
1 | "Inward" mode (Pumping gas from the outside to the connected pipe network.) |
2 | (Unknown) |
Data Parameters
These are all parameters, that can be written to with a Logic Writer or a Batch Writer. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.
Parameter Name | Data Type | Description |
---|---|---|
Open | Boolean | Opens the Active Vent, when set to 1. Closes it, when set to 0. (Untested) |
Mode | Integer | Sets the Active Vent mode to the passed setting. (See Mode Values) |
PressureExternal | Float | Sets the desired external pressure of the space outside the Active Vent. (Untested) |
PressureInternal | Float | Sets the desired internal pressure of the pipe network, connected to the Active Vent. (Untested) |
Lock | Boolean | Locks the Active Vent, when set to 1. Unlocks it, when set to 0. |
Setting | Float | Takes a range from 0.0 to 100.0. (Assumption) This sets the percentage amount of pumping throughput of the Active Vent. |
On | Boolean | Turns the Active Vent on, when set to 1. Turns it off, when set to 0. |
Data Outputs
These are all parameters, that can be read with a Logic Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Active Vent is receiving power and is turned on. (0 for no, 1 for yes) |
Open | Boolean | Returns whether the Active Vent is open. (0 for no, 1 for yes) (Untested) |
Mode | Integer | Returns the setting of the current mode of the Active Vent. (See Mode Values) |
Error | Boolean | Returns whether the Active Vent is currently flashing an error. (0 for no, 1 for yes) |
PressureExternal | Float | Returns the desired external pressure of the Active Vent. (Untested) |
PressureInternal | Float | Returns the desired internal pressure of the Active vent. (Untested) |
Lock | Boolean | Returns whether the Active Vent is locked. (0 for no, 1 for yes) |
Setting | Float | Returns a range from 0.0 to 100.0. (Assumption) Returns the percentage amount of pumping throughput of the Active Vent. |
Maximum | Integer | Returns 100. (Assumption) Returns the maximum throughput percentage of the Active Vent. |
Ratio | Float | Returns a range from 0.0 to 1.0. (Assumption) Returns the percentage amount of pumping throughput of the Active Vent. |
On | Boolean | Returns whether the Active Vent is set to on. (0 for no, 1 for yes) |
RequiredPower | Integer | Returns the current amount of power needed for the Active Vent. |