Kit (Switch) provides a range of simple input devices for controlling station machinery. Switches do not require power to function and lack the associated connection port.
 +
 +
At the minimum, any Switch has to be paired with a [[Logic Writer]] to direct its output signal into desired data variable of a given device or machine.
  
 
{{Data Network Header}}
 
{{Data Network Header}}
Line 152: Line 156:
 
! Parameter Name !! Data Type !! Description
 
! Parameter Name !! Data Type !! Description
 
|-
 
|-
| Mode || Boolean || Sets the maximum value you can set when using the dial
+
| Mode || Integer || Sets the maximum value you can set when using the dial
 
|-
 
|-
 
| Setting || Integer || Sets the current value of the dial
 
| Setting || Integer || Sets the current value of the dial
Line 163: Line 167:
 
! Output Name !! Data Type !! Description
 
! Output Name !! Data Type !! Description
 
|-
 
|-
| Mode || Boolean || Gets the maximum value you can set when using the dial
+
| Mode || Integer || Gets the maximum value you can set when using the dial
 
|-
 
|-
 
| Setting || Integer || Get the current value of the dial
 
| Setting || Integer || Get the current value of the dial

Latest revision as of 18:58, 15 October 2025

Kit (Switch)
Recipe
Created With Electronics Printer, Fabricator
Cost 1g Gold, 1g Copper
Switch
Switch.jpg
Operation
Power Usage 0W
Prefab Hash 321604921
Construction
Placed with Kit (Logic Switch)
Placed on Small Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Logic Switch)
Lever
Lever.jpg
Operation
Power Usage 0W
Prefab Hash 1220484876
Construction
Placed with Kit (Logic Switch)
Placed on Small Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Logic Switch)
Button
Button.jpg
Operation
Power Usage 0W
Prefab Hash 491845673
Construction
Placed with Kit (Logic Switch)
Placed on Small Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Logic Switch)
Dial
Dial.jpg
Operation
Power Usage 0W
Prefab Hash 554524804
Construction
Placed with Kit (Logic Switch)
Placed on Small Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Logic Switch)


Kit (Switch) provides a range of simple input devices for controlling station machinery. Switches do not require power to function and lack the associated connection port.

At the minimum, any Switch has to be paired with a Logic Writer to direct its output signal into desired data variable of a given device or machine.

Data Network Properties[edit]

These are all Data Network properties of this device.

Switch[edit]

The Logic Switch gives players the ability to add controls to control circuits without requiring tools. Toggles output value between 0 and 1.

Data Parameters[edit]

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).


Parameter Name Data Type Description
Lock Boolean Prevents using the switch when set to 1 (not working as of v0.2.2891.14453)
Open Boolean Set the current switch state

Data Outputs[edit]

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Lock Boolean Gets the current lock state
Setting Integer
PrefabHash String
Open Boolean Gets the current state

Connectors[edit]

  • Top: Data Output
  • Bottom: Data Output

Lever[edit]

Toggles output value between 0 and 1.

Data Parameters[edit]

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).


Parameter Name Data Type Description
Open Boolean Sets the lever position
Lock Boolean Locks or unlocks the lever for player interaction (Does not appear to work in v. 0.2.4089.19416)

Data Outputs[edit]

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Open Boolean What state the lever is in
Lock Boolean Whether the lever is locked from user interaction
Setting Integer(?)  ?
PrefabHash String

Connectors[edit]

  • Top: Data Output
  • Bottom: Data Output

Button[edit]

Sends a pulse of 0.5 seconds long of value 1.

Data Parameters[edit]

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).


Parameter Name Data Type Description
Activate Boolean Sets the button setting to 1

Data Outputs[edit]

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Activate Boolean Returns 1 if the activate state was just set by a write or IC
Setting Integer Gets the current value of the button
PrefabHash String

Connectors[edit]

  • Top: Data Output
  • Bottom: Data Output

Dial[edit]

Allows user to select a value between 0 and the maximum set by use of screws.

Data Parameters[edit]

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).


Parameter Name Data Type Description
Mode Integer Sets the maximum value you can set when using the dial
Setting Integer Sets the current value of the dial

Data Outputs[edit]

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Mode Integer Gets the maximum value you can set when using the dial
Setting Integer Get the current value of the dial
PrefabHash String
Ratio Integer

Connectors[edit]

  • Bottom: Data Output

Screws[edit]

  • Bottom Left: Decrease maximum possible value to be set by dial.