Difference between revisions of "Powered Vent"
From Unofficial Stationeers Wiki
m (edit) |
(added new info) |
||
| Line 55: | Line 55: | ||
strong as 5-6 active vent. | strong as 5-6 active vent. | ||
strong as 11-12 passive vent. | strong as 11-12 passive vent. | ||
| + | |||
| + | {{Data Network Header}} | ||
| + | === Mode Values === | ||
| + | These list the values and meanings for the "Mode" property of the Power Vent/Large. | ||
| + | {| class="wikitable" | ||
| + | |- | ||
| + | ! Value !! Meaning | ||
| + | |- | ||
| + | | 0 || "Outward" mode (Moves gas from the connected pipe network to the surrounding atmosphere.) | ||
| + | |- | ||
| + | | 1 || "Inward" mode (Moves gas from the surrounding atmosphere to the connected pipe network.) | ||
| + | |} | ||
| + | {{Data Parameters| | ||
| + | {{Data Parameters/row|Power|Boolean|w=0|Can be read to return if the device is correctly powered or not, set via the power system, returns 1 if powered and 0 if not|multiple=2|0|Off|1|On}} | ||
| + | {{Data Parameters/row|PressureExternal|Float|<div>"Outward" mode: Maximum pressure of the surrounding atmosphere. Default 101.325 (kPa).<br> | ||
| + | "Inward" mode: Minimum pressure of the surrounding atmosphere. Default 0 (kPa).</div>}} | ||
| + | {{Data Parameters/row|Mode|Integer|The mode of the Power Vent.|multiple=2|0|Outward|1|Inward}} | ||
| + | {{Data Parameters/row|Lock|Boolean|Disable manual operation of the Power Vent.|multiple=2|0|Unlocked|1|Locked}} | ||
| + | {{Data Parameters/row|On|Boolean|The current state of the Power Vent.|multiple=2|0|Off|1|On}} | ||
| + | {{Data Parameters/row|RequiredPower|Integer|w=0|Idle operating power quantity, does not necessarily include extra demand power}} | ||
| + | {{Data Parameters/row|PrefabHash|Integer|w=0|The hash of the structure}} | ||
| + | {{Data Parameters/row|ReferenceId|Integer|w=0|Unique Reference Identifier for this object}} | ||
| + | {{Data Parameters/row|NameHash|Integer|w=0|Provides the hash value for the name of the object as a 32-bit integer.}} | ||
| + | }} | ||
Revision as of 16:07, 10 August 2025
![]() | |
| Constructing Options | Powered Vent, Powered Vent Large |
|---|---|
| Properties | |
| Stacks | Yes (5) |
| Recipes | |
| Hydraulic Pipe Bender (Tier Two) | 5g Steel, 5g Electrum, 2g Invar |
| Logic | |
| Item Hash | 2015439334 |
| Item Name | ItemKitPoweredVent |
| Logic Classes |
SlotClass.None SortingClass.Kits |
| File:StructurePoweredVent.png | |
| Operation | |
|---|---|
| Power Usage | 250W |
| Prefab Hash | 938836756 |
| Prefab Name | StructurePoweredVent |
| Construction | |
| Placed with | Kit (Powered Vent) |
| Placed on | Small Grid |
| Stage 1 | |
| Next Stage Construction | |
| Constructed with tool | Screwdriver |
| Constructed with item | 2 x Kit (Pipe) |
| Deconstruction | |
| Deconstructed with | Hand Drill |
| Item received | Kit (Powered Vent) |
| Stage 2 | |
| Next Stage Construction | |
| Constructed with tool | Welding Torch |
| Constructed with item | 2 x Plastic Sheets |
| Deconstruction | |
| Deconstructed with | Wrench |
| Stage 3 | |
| Deconstruction | |
| Deconstructed with | Angle Grinder |
| File:StructurePoweredVentLarge.png | |
| Operation | |
|---|---|
| Power Usage | 500W |
| Prefab Hash | -785498334 |
| Prefab Name | StructurePoweredVentLarge |
| Construction | |
| Placed with | Kit (Powered Vent) |
| Placed on | Small Grid |
| Stage 1 | |
| Next Stage Construction | |
| Constructed with tool | Screwdriver |
| Constructed with item | 2 x Electronic Parts |
| Deconstruction | |
| Deconstructed with | Hand Drill |
| Item received | Kit (Powered Vent) |
| Stage 2 | |
| Next Stage Construction | |
| Constructed with tool | Welding Torch |
| Constructed with item | 4 x Plastic Sheets |
| Deconstruction | |
| Deconstructed with | Wrench |
| Stage 3 | |
| Deconstruction | |
| Deconstructed with | Angle Grinder |
Contents
Powered Vent
Great for moving large quantities of air into a pipe network. its primary purpose is for the creation of multi-grid airlocks. it can efficiently pull a vacuum on a s small to medium sized room. strong as 3-4 Active vent. strong as 5-6 passive vent.
Powered Vent Large
For building large scale airlock systems and pressurized hangars, a bigger and bolder version of the powered vent that can efficiently pull a vacuum in large room. strong as 5-6 active vent. strong as 11-12 passive vent.
Data Network Properties
These are all Data Network properties of this device.
Mode Values
These list the values and meanings for the "Mode" property of the Power Vent/Large.
| Value | Meaning |
|---|---|
| 0 | "Outward" mode (Moves gas from the connected pipe network to the surrounding atmosphere.) |
| 1 | "Inward" mode (Moves gas from the surrounding atmosphere to the connected pipe network.) |
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).
| Parameter Name | Data Type | Access | Value | Description | ||
|---|---|---|---|---|---|---|
| Power | Boolean | Read
|
0 | Off | Can be read to return if the device is correctly powered or not, set via the power system, returns 1 if powered and 0 if not | |
| 1 | On | |||||
| PressureExternal | Float | Read Write
|
||||
| Mode | Integer | Read Write
|
0 | Outward | The mode of the Power Vent. | |
| 1 | Inward | |||||
| Lock | Boolean | Read Write
|
0 | Unlocked | Disable manual operation of the Power Vent. | |
| 1 | Locked | |||||
| On | Boolean | Read Write
|
0 | Off | The current state of the Power Vent. | |
| 1 | On | |||||
| RequiredPower | Integer | Read
|
||||
| PrefabHash | Integer | Read
|
||||
| ReferenceId | Integer | Read
|
||||
| NameHash | Integer | Read
|
||||