Difference between revisions of "Pressure Regulator"
From Unofficial Stationeers Wiki
(→Description) |
(→Description) |
||
| (7 intermediate revisions by 4 users not shown) | |||
| Line 1: | Line 1: | ||
| − | + | {{Structurebox | |
| − | {{ | + | | name = Pressure Regulator |
| − | + | | image = [[File:ItemKitRegulator.png ]] | |
| − | + | | prefab_hash = 209854039 | |
| − | + | | prefab_name = StructurePressureRegulator | |
| − | + | | power_usage = 100W | |
| − | + | | placed_on_grid = Small Grid | |
| − | + | | decon_with_tool1 = [[Hand Drill]] | |
| + | | placed_with_item = [[Kit (Pressure Regulator)]] | ||
| + | | item_rec1 = [[Kit (Pressure Regulator)]] | ||
}} | }} | ||
| − | |||
| − | |||
| − | |||
| − | + | ==Description== | |
| + | <blockquote><q>Controlling the flow of gas between two pipe networks, pressure regulators shift gas until a set pressure on the outlet side is achieved, or the gas supply is exhausted. The back pressure regulator, by contrast, will only operate when pressure on the intake side exceeds the set value. With a max pressure of over 20,000kPa, it requires power to operate.</q><br> | ||
| + | '''- Stationpedia'''</blockquote> | ||
| − | Pressure | + | The standard Pressure Regulator is an active powered device for controlled transfer of substances between the two pipe networks. Pressure Regulator will use the gas from Input pipe network to pressurize the Output pipe network until a target pressure defined by the valve setting is reached or exceeded, or unless the input pipe runs dry. When being placed, hologram indicators will display the Input pipe arrow inward, the Output pipe arrow outward, and the power socket on its side. It has a pressure control valve, which defines the target pressure. |
| − | + | The most common use for a standard Pressure Regulator is to place one ahead of a [[Gas Tank Storage]] unit to safely fill the inserted [[Gas Canister]] or [[Gas Canister (Smart)]] with gas input without overpressurizing it. Similar principle can be used to maintain the desired pressure level in any pipe network or room. | |
| − | |||
| − | |||
| − | + | The maximum pressure setting is 60795 kPa - a critical pressure limit for a pipe network before it begin to take damage. | |
| − | |||
| − | The | ||
| − | |||
| − | |||
| − | |||
| − | |||
To calculate the moles per tick, use the following equation: | To calculate the moles per tick, use the following equation: | ||
| Line 39: | Line 32: | ||
{{Data Network Header}} | {{Data Network Header}} | ||
| − | + | {{Data Parameters| | |
| − | {{Data Parameters | + | {{Data Parameters/row|Power|Boolean|w=0|Can be read to return if the Pressure Regulator is correctly powered or not, set via the power system, return 1 if powered and 0 if not|multiple=2|0|Unpowered|1|Powered}} |
| − | { | + | {{Data Parameters/row|Error|Boolean|w=0|1 if device is in error state, otherwise 0|multiple=2|0|<p></p>|1|Error}} |
| − | + | {{Data Parameters/row|Lock|Boolean|Disable manual operation of the Pressure Regulator.|multiple=2|0|Unlocked|1|Locked}} | |
| − | + | {{Data Parameters/row|Setting|Integer|A variable setting that can be read or written.|0.0 to 60795.0}} | |
| − | + | {{Data Parameters/row|Maximum|Float|w=0|Maximum setting of the Pressure Regulator}} | |
| − | + | {{Data Parameters/row|Ratio|Float|w=0|Context specific value depending on device, 0 to 1 based ratio|0.0 to 1.0}} | |
| − | | | + | {{Data Parameters/row|On|Boolean|The current state of the Pressure Regulator.|multiple=2|0|Off|1|On}} |
| − | + | {{Data Parameters/row|RequiredPower|Integer|w=0|Idle operating power quantity, does not necessarily include extra demand power}} | |
| − | + | {{Data Parameters/row|PrefabHash|Integer|w=0|The hash of the structure}} | |
| − | + | {{Data Parameters/row|ReferenceId|Integer|w=0|Unique Reference Identifier for this object}} | |
| − | + | {{Data Parameters/row|NameHash|Integer|w=0|Provides the hash value for the name of the object as a 32 bit integer.}} | |
| − | + | }} | |
| − | {{Data | + | [[Category:Atmospherics]] |
| − | |||
| − | | | ||
| − | |||
| − | | | ||
| − | | | ||
| − | | | ||
| − | | | ||
| − | | | ||
| − | | | ||
| − | |||
| − | | Setting || | ||
| − | |||
| − | | Maximum || | ||
| − | |||
| − | | Ratio | ||
| − | | | ||
| − | | | ||
| − | | | ||
| − | | | ||
| − | | | ||
| − | | | ||
| − | |||
| − | = | ||
| − | |||
| − | The | ||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | {{Data | ||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
Latest revision as of 12:38, 18 May 2025
![]() | |
| Operation | |
|---|---|
| Power Usage | 100W |
| Prefab Hash | 209854039 |
| Prefab Name | StructurePressureRegulator |
| Construction | |
| Placed with | Kit (Pressure Regulator) |
| Placed on | Small Grid |
| Stage 1 | |
| Deconstruction | |
| Deconstructed with | Hand Drill |
| Item received | Kit (Pressure Regulator) |
Description[edit]
Controlling the flow of gas between two pipe networks, pressure regulators shift gas until a set pressure on the outlet side is achieved, or the gas supply is exhausted. The back pressure regulator, by contrast, will only operate when pressure on the intake side exceeds the set value. With a max pressure of over 20,000kPa, it requires power to operate.
- Stationpedia
The standard Pressure Regulator is an active powered device for controlled transfer of substances between the two pipe networks. Pressure Regulator will use the gas from Input pipe network to pressurize the Output pipe network until a target pressure defined by the valve setting is reached or exceeded, or unless the input pipe runs dry. When being placed, hologram indicators will display the Input pipe arrow inward, the Output pipe arrow outward, and the power socket on its side. It has a pressure control valve, which defines the target pressure.
The most common use for a standard Pressure Regulator is to place one ahead of a Gas Tank Storage unit to safely fill the inserted Gas Canister or Gas Canister (Smart) with gas input without overpressurizing it. Similar principle can be used to maintain the desired pressure level in any pipe network or room.
The maximum pressure setting is 60795 kPa - a critical pressure limit for a pipe network before it begin to take damage.
To calculate the moles per tick, use the following equation: n = (P * V) / (R * T)
Where:
- P = Min(Input pressure, 101.325)
- V = (OutputPipeVolume / InputPipeVolume) * 100
- n = Moles per tick
- R = Gas constant (8.3144)
- T = Input temperature
Data Network Properties[edit]
These are all Data Network properties of this device.
Data Parameters[edit]
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).
| Parameter Name | Data Type | Access | Value | Description | ||
|---|---|---|---|---|---|---|
| Power | Boolean | Read
|
0 | Unpowered | Can be read to return if the Pressure Regulator is correctly powered or not, set via the power system, return 1 if powered and 0 if not | |
| 1 | Powered | |||||
| Error | Boolean | Read
|
0 | 1 if device is in error state, otherwise 0 | ||
| 1 | Error | |||||
| Lock | Boolean | Read Write
|
0 | Unlocked | Disable manual operation of the Pressure Regulator. | |
| 1 | Locked | |||||
| Setting | Integer | Read Write
|
0.0 to 60795.0 | |||
| Maximum | Float | Read
|
||||
| Ratio | Float | Read
|
0.0 to 1.0 | |||
| On | Boolean | Read Write
|
0 | Off | The current state of the Pressure Regulator. | |
| 1 | On | |||||
| RequiredPower | Integer | Read
|
||||
| PrefabHash | Integer | Read
|
||||
| ReferenceId | Integer | Read
|
||||
| NameHash | Integer | Read
|
||||

