Actions

Difference between revisions of "Pipe Volume Pump"

From Unofficial Stationeers Wiki

(Fixed error: requires 20W per liter, not 2)
(update max flow rate 100L to 10L)
Line 37: Line 37:
 
| Lock || Boolean ||  
 
| Lock || Boolean ||  
 
|-
 
|-
| Setting || Integer || Sets the flow rate between 0 - 100 Liters
+
| Setting || Integer || Sets the flow rate between 0 - 10 Liters
 
|-
 
|-
 
| On || Boolean ||  
 
| On || Boolean ||  

Revision as of 16:09, 23 February 2024

Other languages:
English
Pipe Volume Pump
ItemPipeVolumePump.png
Properties
Stacks Yes (5)
Recipe
Created With Hydraulic Pipe Bender, Fabricator
Cost 5g Iron, 2g Gold, 3g Copper


Description

Used to pump gasses throughout a pipe, featuring an adjustable valve 0-10 Liters and requiring power (20W per Liter). All the gasses in the pipes behind it will be completely pushed in front of it when powered, and blocks any flow of gasses in either direction when unpowered.

Note that valve settings are for the rate at which the pump operates, in volume per tick (0.5 seconds).

To calculate the moles per tick, use the following equation: n = (P * V) / (R * T)

Where:

  • P = Input pressure
  • V = The volume you set
  • n = Moles per tick
  • R = Gas constant (8.3144)
  • T = Input temperature (in Kelvin)

Data Network Properties

These are all Data Network properties of this device.

Data Parameters

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).


Parameter Name Data Type Description
Lock Boolean
Setting Integer Sets the flow rate between 0 - 10 Liters
On Boolean

Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Maximum
Lock Boolean
Error
Setting
RequiredPower
Ratio
PrefabHash
Power
On