Difference between revisions of "Dock Port Side"
From Unofficial Stationeers Wiki
F1r3w4rr10r (talk | contribs) (Update to use the new Data Network templates) |
m (fixed small mistake) |
||
(3 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
+ | {{deprecated}}[[Category:Deprecated]] | ||
[[Category:Atmospherics]][[Category:Data Network]] | [[Category:Atmospherics]][[Category:Data Network]] | ||
{{Itembox | {{Itembox | ||
Line 46: | Line 47: | ||
| RequiredPower || Integer || Returns the current amount of power, required by the Docking Port, in Watts. | | RequiredPower || Integer || Returns the current amount of power, required by the Docking Port, in Watts. | ||
|} | |} | ||
+ | |||
+ | ==Images== | ||
+ | [[File:Stationeers-docking-port-1.png|thumb|A view of the two shapes possible from a [Kit (Docking Port)]]] | ||
+ | [[File:Stationeers-docking-port-2.png|thumb|The same two ports from the other side]] | ||
== Bugs == | == Bugs == | ||
* The Docking Port can not be powered, as indicated by the RequiredPower of -1W. | * The Docking Port can not be powered, as indicated by the RequiredPower of -1W. |
Latest revision as of 11:54, 21 December 2023
Warning: | This item is deprecated. |
Properties | |
---|---|
Stacks | Yes (5) |
Operation | |
---|---|
Power Usage | -1W |
Construction | |
Placed with | Kit (Docking Port) |
Placed on | Large Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Docking Port) |
Data Network Properties[edit]
These are all Data Network properties of this device.
Data Parameters[edit]
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Open | Boolean | Opens the Docking Port, when set to 1. Closes the it, when set to 0. |
Lock | Boolean | Locks the Docking Port, when set to 1. Unlocks it, when set to 0. |
On | Boolean | Turns the Docking Port on, when set to 1. Turns the Docking Port off, when set to 0. |
Data Outputs[edit]
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Docking Port is turned on and receives power. (0 for no, 1 for yes) (Assumption) |
Open | Boolean | Returns whether the Docking Port is open. (0 for no, 1 for yes) |
Lock | Boolean | Returns whether the Docking Port is locked. (0 for no, 1 for yes) |
On | Boolean | Returns whether the Docking Port is turned on. (0 for no, 1 for yes) |
RequiredPower | Integer | Returns the current amount of power, required by the Docking Port, in Watts. |
Images[edit]
Bugs[edit]
- The Docking Port can not be powered, as indicated by the RequiredPower of -1W.