Used to pump gasses throughout a pipe, featuring an adjustable valve 0-100 Liters and requiring power (2W per Liter). All the gasses in the pipes behind it will be completely pushed in front of it when powered, and blocks any flow of gasses in either direction when unpowered.
 
Used to pump gasses throughout a pipe, featuring an adjustable valve 0-100 Liters and requiring power (2W per Liter). All the gasses in the pipes behind it will be completely pushed in front of it when powered, and blocks any flow of gasses in either direction when unpowered.
  
Note that valve settings are for the rate at which the pump operates, in volume per tick (0.5 seconds).
+
Note that valve settings are for the rate at which the pump operates, in per-mille per tick (0.5 seconds).  At volume=100 the pump moves 10% of the gas on the input pipe to the output pipe.  At volume=10 the pump moves 1% of the gas on the input pipe to the output pipe.
  
To calculate the moles per tick, use the following equation:
+
<!-- To calculate the moles per tick, use the following equation:
 
n = (P * V) / (R * T)
 
n = (P * V) / (R * T)
  
Line 26: Line 26:
 
* n = Moles per tick
 
* n = Moles per tick
 
* R = Gas constant (8.3144)
 
* R = Gas constant (8.3144)
* T = Input temperature
+
* T = Input temperature -->
  
 
{{Data Network Header}}
 
{{Data Network Header}}

Revision as of 20:33, 10 December 2021

Other languages:
English
Pipe Volume Pump
ItemPipeVolumePump.png
Properties
Stacks Yes (5)
Recipe
Created With Hydraulic Pipe Bender, Fabricator
Cost 5g Iron, 2g Gold, 3g Copper


Description

Used to pump gasses throughout a pipe, featuring an adjustable valve 0-100 Liters and requiring power (2W per Liter). All the gasses in the pipes behind it will be completely pushed in front of it when powered, and blocks any flow of gasses in either direction when unpowered.

Note that valve settings are for the rate at which the pump operates, in per-mille per tick (0.5 seconds). At volume=100 the pump moves 10% of the gas on the input pipe to the output pipe. At volume=10 the pump moves 1% of the gas on the input pipe to the output pipe.


Data Network Properties

These are all Data Network properties of this device.

Data Parameters

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).


Parameter Name Data Type Description
Lock Boolean
Setting Integer Sets the flow rate between 0 - 100 Liters
On Boolean

Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Maximum
Lock Boolean
Error
Setting
RequiredPower
Ratio
PrefabHash
Power
On