Difference between revisions of "Wall Cooler"
From Unofficial Stationeers Wiki
m (deleted obsolete entry related to water as coolant gas, changes requirement in the description from "Pipe Radiator" to "Coolant gas pipe", some minor changes in the usage part to avoid misunderstandings) |
|||
(20 intermediate revisions by 12 users not shown) | |||
Line 1: | Line 1: | ||
+ | <languages/> | ||
+ | <translate> | ||
[[Category:Machines]] | [[Category:Machines]] | ||
+ | {{Itembox | ||
+ | | stacks = 5 | ||
+ | | name = Wall Cooler | ||
+ | | createdwith = [[Hydraulic Pipe Bender]], [[Fabricator]] | ||
+ | | cost = 3g [[Iron]], 1g [[Gold]], 3g [[Copper]] | ||
+ | | logic = | ||
+ | }} | ||
{{Structurebox | {{Structurebox | ||
− | | name | + | | name = Wall Cooler |
− | | | + | | image = [[File:{{#setmainimage:WallCooler.png}}]] |
− | | | + | | power_usage = 10W idle + 1000W active |
− | | | + | | placed_with_item = [[Wall Cooler (Item)]] |
+ | | placed_on_grid = Small Grid, On Frames | ||
+ | | decon_with_tool1 = [[Hand Drill]] | ||
+ | | item_rec1 = [[Wall Cooler (Item)]] | ||
}} | }} | ||
− | ==Description== | + | |
+ | ==Description== <!--T:1--> | ||
Used to lower the temperature inside a room. | Used to lower the temperature inside a room. | ||
It will flash an error if certain things are not present like: | It will flash an error if certain things are not present like: | ||
− | * | + | * Coolant gas pipe |
− | * Atmosphere in the room | + | * Atmosphere in the room you're trying to cool (minimum is around 5-8kpa, not sure exactly, will flash an error if too low) |
− | * | + | * Gasses in the coolant pipe (At least 12.5 kpa) |
+ | |||
+ | Game update 0.2.1783.8193 Changed the wall cooler where the efficiency drops as the temperature difference becomes too large. If the waste network becomes 100 degrees warmer than input, efficiency begins to drop until zero at 200 degrees. This is highlighted on the graph on the right. [[File:Cooler Graph.png|thumb|Efficiency drop off]] | ||
+ | |||
+ | ==Usage== <!--T:2--> | ||
+ | Place the Wall Cooler and run some pipes to the place you want to store or vent the heat. Fill the coolant pipe with enough gas and start the machine, it will slowly lower the rooms temperature by transfering its heat to the coolant pipe. | ||
+ | |||
+ | <!--T:3--> | ||
+ | * The wall cooler works by removing 1000 Joules of energy/tick (2000J/s) from the atmosphere and adding it into its pipe. | ||
+ | |||
+ | |||
+ | {{Data Network Header}} | ||
− | = | + | {{Data Parameters}} |
− | + | {| class="wikitable" | |
+ | |- | ||
+ | ! Parameter Name !! Data Type !! Description | ||
+ | |- | ||
+ | | Lock || || | ||
+ | |- | ||
+ | | Setting || Boolean || Unused | ||
+ | |- | ||
+ | | On || || | ||
+ | |} | ||
− | + | {{Data Outputs}} | |
+ | {| class="wikitable" | ||
+ | |- | ||
+ | ! Output Name !! Data Type !! Description | ||
+ | |- | ||
+ | | Power || || | ||
+ | |- | ||
+ | | Error || || | ||
+ | |- | ||
+ | | Lock || || | ||
+ | |- | ||
+ | | Setting || || | ||
+ | |- | ||
+ | | Maximum || || | ||
+ | |- | ||
+ | | Ratio || || | ||
+ | |- | ||
+ | | On || || | ||
+ | |- | ||
+ | | Required Power || || | ||
+ | |} | ||
+ | </translate> |
Latest revision as of 15:58, 28 July 2021
Properties | |
---|---|
Stacks | Yes (5) |
Recipe | |
Created With | Hydraulic Pipe Bender, Fabricator |
Cost | 3g Iron, 1g Gold, 3g Copper |
Operation | |
---|---|
Power Usage | 10W idle + 1000W active |
Construction | |
Placed with | Wall Cooler (Item) |
Placed on | Small Grid, On Frames |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Wall Cooler (Item) |
Description[edit]
Used to lower the temperature inside a room. It will flash an error if certain things are not present like:
- Coolant gas pipe
- Atmosphere in the room you're trying to cool (minimum is around 5-8kpa, not sure exactly, will flash an error if too low)
- Gasses in the coolant pipe (At least 12.5 kpa)
Usage[edit]
Place the Wall Cooler and run some pipes to the place you want to store or vent the heat. Fill the coolant pipe with enough gas and start the machine, it will slowly lower the rooms temperature by transfering its heat to the coolant pipe.
- The wall cooler works by removing 1000 Joules of energy/tick (2000J/s) from the atmosphere and adding it into its pipe.
Data Network Properties[edit]
These are all Data Network properties of this device.
Data Parameters[edit]
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Lock | ||
Setting | Boolean | Unused |
On |
Data Outputs[edit]
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | ||
Error | ||
Lock | ||
Setting | ||
Maximum | ||
Ratio | ||
On | ||
Required Power |