Actions

Kit (Vending Machine Refrigerated)

From Unofficial Stationeers Wiki

Kit (Vending Machine Refrigerated)
ItemKitVendingMachineRefrigerated.png
Stacks No
Constructing Options Vending Machine
Recipe
Created With Electronics Printer, Fabricator
Cost 60g Gold, 40g Steel, 80g Electrum, 30g Solder
Vending Machine Refrigerated
ItemVendingMachineRefrigerated.png
Holds 100 individual stacks of items.
Operation
Power Usage 5W
Prefab Hash -1577831321
Construction
Placed with Kit (Vending Machine Refrigerated)
Placed on Small Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Vending Machine Refrigerated)

Description[edit]

The Vending Machine Refrigerated is a machine used to dispense items to players. The machine can hold up to 100 individual stacks of items. The machine's easy to use interface lets the user choose an item (displayed in the picture window) and dispense it with the press of a button. Differently from the standard Vending Machine, will reduce the spoil time of organic items inside of it.

It has a frontal dial used to manually regulate the out stack size of asked item. This stacksize setting does not apply to ingots. The entire ingot is dispensed. The stacksize setting is not a data parameter accessible to logic.
Can be also used to get the items purchased or sold to Traders.

Data Network Properties[edit]

These are all Data Network properties of this device.

Data Parameters[edit]

These are all parameters, that can be written to with a Logic Writer, Batch Writer, or Integrated Circuit (IC10). The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.

Parameter Name Data Type Description
Activate Boolean Not functional on this device
Lock Boolean Locks the device for player interaction when set to 1. Unlocks it, when set to 0.
On Boolean Turns the device on, when set >= 1. Turns it off, when set to <1.
RequestHash Integer Write ItemHash to device to immediate output

Data Outputs[edit]

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Power Boolean Returns whether the device is turned on and receives power. (0 for no, 1 for yes).
Error Boolean Returns whether the device is flashing an error. (0 for no, 1 for yes).
Activate Boolean Not functional on this device.
Lock Boolean Reads if the device is locked.
ImportCount Integer Incremented each time an item stack enter by the Import slot
ExportCount Integer Incremented each time an item stack exit by the Export Slot
Ratio Integer Storage space used in percentage.
Quantity Integer Storage space used in whole numbers.
PrefabHash Integer Returns ItemHash of device
On Boolean Returns whether the device is turned on. (0 for no, 1 for yes)
RequiredPower Integer Returns the current amount of power, required by the device, in watts.
RequestHash Integer 0 unless actively written to
RatioOxygen Float Returns a range from 0.0 to 1.0. Returns the percentage ratio of the amount of oxygen in the Vending Machine Refrigerated.
RatioCarbonDioxide Float Returns a range from 0.0 to 1.0. Returns the percentage ratio of the amount of carbon dioxide in the Vending Machine Refrigerated.
RatioNitrogen Float Returns a range from 0.0 to 1.0. Returns the percentage ratio of the amount of nitrogen in the Vending Machine Refrigerated.
RatioPollutant Float Returns a range from 0.0 to 1.0. Returns the percentage ratio of the amount of pollutant in the Vending Machine Refrigerated.
RatioVolatiles Float Returns a range from 0.0 to 1.0. Returns the percentage ratio of the amount of volatiles in the Vending Machine Refrigerated.
RatioWater Float Returns a range from 0.0 to 1.0. Returns the percentage ratio of the amount of water in the Vending Machine Refrigerated.
Temperature Float Returns the temperature in the Vending Machine Refrigerated.
TotalMoles Float Totale moles inside the Vending Machine Refrigerated.

Data Slots[edit]

These are all parameters, that can be read with a Slots Reader. The outputs are listed in the order a Slots Reader's "VAR" setting cycles through them.

Number Name Description
0 Import Import slot.
1 Export Export slot.
2-101 Storage Internal storage slots.o
Name Data Type Description
Occupied Boolean Returns whether the slot occupied. (0 for no, 1 for yes).
OccupantHash Integer Returns ItemHash of item in slot.
Quantity Integer Size of stack.
Damage Integer Item durability in percent.
Class Integer Item class ID.

Notes[edit]

  • Seems that the inside temperature and atmosphere are fixed on 142K and vacuum atmosphere.