Kit (Switch)
From Unofficial Stationeers Wiki
(Redirected from Kit (Logic Switch) Lever)
Recipe | |
---|---|
Created With | Electronics Printer, Fabricator |
Cost | 1g Gold, 1g Copper |
Operation | |
---|---|
Power Usage | 0W |
Prefab Hash | 321604921 |
Construction | |
Placed with | Kit (Logic Switch) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Logic Switch) |
Operation | |
---|---|
Power Usage | 0W |
Prefab Hash | 1220484876 |
Construction | |
Placed with | Kit (Logic Switch) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Logic Switch) |
Operation | |
---|---|
Power Usage | 0W |
Prefab Hash | 491845673 |
Construction | |
Placed with | Kit (Logic Switch) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Logic Switch) |
Operation | |
---|---|
Power Usage | 0W |
Prefab Hash | 554524804 |
Construction | |
Placed with | Kit (Logic Switch) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Logic Switch) |
Contents
Data Network Properties[edit]
These are all Data Network properties of this device.
Switch[edit]
The Logic Switch gives players the ability to add controls to control circuits without requiring tools. Toggles output value between 0 and 1.
Data Parameters[edit]
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Lock | Boolean | Prevents using the switch when set to 1 (not working as of v0.2.2891.14453) |
Open | Boolean | Set the current switch state |
Data Outputs[edit]
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Lock | Boolean | Gets the current lock state |
Setting | Integer | |
PrefabHash | String | |
Open | Boolean | Gets the current state |
Connectors[edit]
- Top: Data Output
- Bottom: Data Output
Lever[edit]
Toggles output value between 0 and 1.
Data Parameters[edit]
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Open | Boolean | Sets the lever position |
Lock | Boolean | Locks or unlocks the lever for player interaction (Does not appear to work in v. 0.2.4089.19416) |
Data Outputs[edit]
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Open | Boolean | What state the lever is in |
Lock | Boolean | Whether the lever is locked from user interaction |
Setting | Integer(?) | ? |
PrefabHash | String |
Connectors[edit]
- Top: Data Output
- Bottom: Data Output
Button[edit]
Sends a pulse of 0.5 seconds long of value 1.
Data Parameters[edit]
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Activate | Boolean | Sets the button setting to 1 |
Data Outputs[edit]
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Activate | Boolean | Returns 1 if the activate state was just set by a write or IC |
Setting | Integer | Gets the current value of the button |
PrefabHash | String |
Connectors[edit]
- Top: Data Output
- Bottom: Data Output
Dial[edit]
Allows user to select a value between 0 and the maximum set by use of screws.
Data Parameters[edit]
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Mode | Boolean | Sets the maximum value you can set when using the dial |
Setting | Integer | Sets the current value of the dial |
Data Outputs[edit]
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Mode | Boolean | Gets the maximum value you can set when using the dial |
Setting | Integer | Get the current value of the dial |
PrefabHash | String | |
Ratio | Integer |
Connectors[edit]
- Bottom: Data Output
Screws[edit]
- Bottom Left: Decrease maximum possible value to be set by dial.
- Bottom Right: Increase maximum possible value to be set by dial.