Actions

Elevator

From Unofficial Stationeers Wiki

(Redirected from Kit (Elevator))
Kit (Elevator)
ItemKitElevator.png
Stacks 5
Constructing Options Elevator Shaft, Elevator Level
Recipe
Created With Electronics Printer, Fabricator
Cost 2g Copper, 4g Gold, 2g Steel, 2g Solder


Description[edit]

The elevator allows easy travel to other floors.

Use[edit]

Elevators allow easy access to other floors. They operate using two placement types: elevator level for floors where the elevator stops, and elevator shaft for those where they don't.
Logic and enumeration are automatically applied, and the elevator car is created when building a level.

All levels and shafts must face the same direction, so that their spines align..
Warning: All elevator-placements need to be connected. Otherwise it seems like one elevator but in reality you build several stacked and won't be able to travel from level to level.


Elevator Shaft[edit]

Elevator Shaft
Elevator Shaft front.png
Operation
Power Usage 5W
Construction
Placed with Kit (Elevator)
Placed on Large Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Elevator)

The shaft section to build on floors it should not open like floor frames etc.
Currently does not require power.

Data Network Properties[edit]

These are all Data Network properties of this device.

Data Parameters[edit]

These are all parameters, that can be written to with a Logic Writer, Batch Writer, or Integrated Circuit (IC10). The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.

Parameter Name Data Type Description
On Boolean Turns the device on, when set >= 1. Turns it off, when set to <1.
ElevatorSpeed Integer Sets the desired speed of the elevator. (0.5 - 20)
ElevatorLevel Integer When written to, makes the carriage go to that level.

Data Outputs[edit]

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Power Boolean Returns whether the device is turned on and receives power. (0 for no, 1 for yes)
On Boolean Returns whether the device is turned on. (0 for no, 1 for yes)
RequiredPower Integer Returns the current amount of power, required by the device, in watts.
ElevatorSpeed Integer Returns the current speed setting. (0.5 - 20)
ElevatorLevel Integer Returns current level carriage is on

Elevator Level[edit]

Elevator Level
Elevator Level front.png
Operation
Power Usage 5W
Construction
Placed with Kit (Elevator)
Placed on Large Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Elevator)

The elevator level provides an entrance/exit stop for the elevator car.
Requires power to open the door automatically and use the call button

Data Network Properties[edit]

These are all Data Network properties of this device.

Data Parameters[edit]

These are all parameters, that can be written to with a Logic Writer, Batch Writer, or Integrated Circuit (IC10). The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.

Parameter Name Data Type Description
Open Boolean Opens the device , when set >= 1. Closes it, when set to < 1.
Lock Boolean Locks the device , when set >= 1. Unlocks it, when set to <1.
On Boolean Turns the device on, when set >= 1. Turns it off, when set to <1.
ElevatorSpeed Integer Sets the desired speed of the elevator. (0.5 - 20)
Elevatorlevel Integer When written to, makes the carriage go to that level.


Data Outputs[edit]

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Power Boolean Returns whether the device is turned on and receives power. (0 for no, 1 for yes)
Open Boolean Returns whether the device is open. (0 for no, 1 for yes)
Error Boolean Returns whether the device is flashing an error. (0 for no, 1 for yes)
Lock Boolean Returns whether the device is locked. (0 for no, 1 for yes)
On Boolean Returns whether the device is turned on. (0 for no, 1 for yes)
RequiredPower Integer Returns the current amount of power, required by the Glass Door, in watts.
ElevatorSpeed Integer Returns the current speed setting. (0.5 - 20)
ElevatorLevel Integer Returns current level carriage is on