Blast Doors
From Unofficial Stationeers Wiki
(Redirected from Kit (Blast Doors))
Operation | |
---|---|
Power Usage | 25W |
Burst Pressure | Infinite |
Prefab Hash | 337416191 |
Prefab Name | StructureBlastDoor |
Construction | |
Placed with | Kit (Blast Door) |
Placed on | Small Grid |
Stage 1 | |
Next Stage Construction | |
Constructed with tool | Welding Torch |
Constructed with item | 3 x Steel Sheets |
Deconstruction | |
Deconstructed with | Wrench |
Item received | Kit (Blast Door) |
Stage 2 | |
Next Stage Construction | |
Constructed with tool | Crowbar |
Constructed with item | 3 x Steel Sheets |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | 3 x Steel Sheets |
Stage 3 | |
Deconstruction | |
Deconstructed with | Angle Grinder |
Item received | 3 x Steel Sheets |
Contents
Purpose[edit]
A Blast Door is a powered Portal that will withstand extreme forces.
Characteristics[edit]
- It has no limit to the Pressure it can constrain.
- It has a very high resistance to Damage.
- It consumes 25W of Power per Tick.
- It can be used as an Airlock portal.
- It has a separate Power Port and Data Port.
- It has indicator lights.
- If both unlocked and unpowered, it can be manually operated using a Crowbar.
- If enslaved by a regular or a advanced airlock circuit, it cannot be operated manually.
As long as the door is both unlocked and unpowered, it can be manually operated using a crowbar.
User Interface[edit]
A Blast Door provides the following user interface:
Name | Type | Function |
---|---|---|
Lock | Indicator | Turns red when locked and green when unlocked |
Since a Blast Door has no keypads to operate, they must be controlled by one of:
- Circuitboard (Advanced Airlock)
- Circuitboard (Airlock)
- Door Control
- Logic Writer
- Motherboard (Logic) in a Computer
Construction[edit]
A Blast Door is constructed using 1 x Kit (Blast Door).
Deconstruction[edit]
A Blast Door can be deconstructed at any time using a Hand Drill.
Data Network Properties[edit]
These are all Data Network properties of this device.
Data Parameters[edit]
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).
Click here to see/hide all the data network properties
Parameter Name | Data Type | Access | Value | Description | ||
---|---|---|---|---|---|---|
Power | Boolean | Read
|
0 | Unpowered | Can be read to return if the Blast Door is correctly powered or not, set via the power system, return 1 if powered and 0 if not | |
1 | Powered | |||||
Open | Integer | Read Write
|
0 | Closed | 1 if device is open, otherwise 0 | |
1 | Open | |||||
Mode | Integer | Read Write
|
0 | Operate | The mode of the Blast Door. | |
1 | Logic | |||||
Lock | Boolean | Read Write
|
0 | Unlocked | Disable manual operation of the Blast Door. | |
1 | Locked | |||||
Setting | Integer | Read Write
|
||||
On | Boolean | Read Write
|
0 | Off | The current state of the Blast Door. | |
1 | On | |||||
RequiredPower | Integer | Read
|
||||
Idle | Integer | Read
|
||||
PrefabHash | Integer | Read
|
||||
ReferenceId | Integer | Read
|
||||
NameHash | Integer | Read
|