Actions

Blast Doors

From Unofficial Stationeers Wiki

(Redirected from Kit (Blast Door) Blast Door)
This page contains changes which are not marked for translation.

Other languages:
English
Blast Door
Blast door.jpg
Operation
Power Usage 25W
Burst Pressure Infinite
Construction
Placed with Kit (Blast Door)
Placed on Large Grid
Stage 1
Next Stage Construction
Constructed with tool Welding Torch
Constructed with item 3 x Steel Sheets
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Blast Door)
Stage 2
Next Stage Construction
Constructed with tool Crowbar
Constructed with item 3 x Glass Sheets
Deconstruction
Deconstructed with (Not checked)
Item received 3 x Steel Sheets
Stage 3
Deconstruction
Deconstructed with (Not checked)
Item received 3 x Steel Sheets

Purpose[edit]

A Blast Door is a powered Portal that will withstand extreme forces.

Characteristics[edit]

  • It has no limit to the Pressure it can constrain.
  • It has a very high resistance to Damage.
  • It consumes 25W of Power per Tick.
  • It can be used as an Airlock portal.
  • It has a separate Power Port and Data Port.
  • It has indicator lights.
  • If both unlocked and unpowered, it can be manually operated using a Crowbar.
  • If enslaved by a regular or a advanced airlock circuit, it cannot be operated manually.

As long as the door is both unlocked and unpowered, it can be manually operated using a crowbar.

User Interface[edit]

A Blast Door provides the following user interface:

Name Type Function
Lock Indicator Turns red when locked and green when unlocked

Since a Blast Door has no keypads to operate, they must be controlled by one of:

Construction[edit]

A Blast Door is constructed using 1 x Kit (Blast Door).

Deconstruction[edit]

A Blast Door can be deconstructed at any time using a Hand Drill.

Data Network Properties[edit]

These are all Data Network properties of this device.

Data Parameters[edit]

These are all parameters, that can be written to with a Logic Writer, Batch Writer, or Integrated Circuit (IC10). The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.

Parameter Name Data Type Description
Open Boolean Opens the Blast Door when set to 1. Closes it when set to 0.
Lock Boolean Locks the Blast Door when set to 1. Unlocks it when set to 0.
On Boolean Turns the Blast Door on when set to 1. Turns it off when set to 0.

Data Outputs[edit]

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Power Boolean Returns whether the Blast Door is turned on and receives power. (0 for no, 1 for yes)
Open Boolean Returns whether the Blast Door is open. (0 for no, 1 for yes)
Lock Boolean Returns whether the Blast Door is locked. (0 for no, 1 for yes)
On Boolean Returns whether the Blast Door is turned on. (0 for no, 1 for yes)
RequiredPower Integer Returns the current amount of power, required by the Blast Door, in watts.

See Also[edit]