Logic Uplink
From Unofficial Stationeers Wiki
![]() | |
| Operation | |
|---|---|
| Power Usage | 50W |
| Prefab Hash | 546002924 |
| Prefab Name | StructureLogicRocketUplink |
| Construction | |
| Placed with | Kit (Rocket Datalink) |
| Placed on | Small Grid |
| Stage 1 | |
| Next Stage Construction | |
| Constructed with tool | Screwdriver |
| Constructed with item | 2 x Cable Coil (Heavy) |
| Deconstruction | |
| Deconstructed with | Hand Drill |
| Item received | Kit (Rocket Datalink) |
| Stage 2 | |
| Next Stage Construction | |
| Constructed with tool | Screwdriver |
| Constructed with item | 2 x Electronic Parts |
| Deconstruction | |
| Deconstructed with | Wire Cutters |
| Item received | 2 x Cable Coil (Heavy) |
| Stage 3 | |
| Next Stage Construction | |
| Constructed with tool | Welding Torch |
| Constructed with item | 2 x Steel Sheets |
| Deconstruction | |
| Deconstructed with | Hand Drill |
| Item received | 2 x Electronic Parts |
| Stage 4 | |
| Deconstruction | |
| Deconstructed with | Angle Grinder |
| Item received | 2 x Steel Sheets |
Description[edit]
This allows planetside logic devices to see rocketside devices on the data networks, so planet's logic systems can still interact with rocket devices.
Use[edit]
Devices on the rocket can be remotely accessed through the Rocket Control Motherboard. Specifically, the motherboard traverses the data network. When an uplink/downlink pair is set up, the motherboard can access devices on the rockets, and the rocket devices become available on the uplink's network.
Data Network Properties[edit]
These are all Data Network properties of this device.
Data Parameters[edit]
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).
Click here to see/hide all the data network properties
| Parameter Name | Data Type | Access | Value | Description | ||
|---|---|---|---|---|---|---|
| Power | Boolean | Read
|
0 | Unpowered | Can be read to return if the Logic Uplink is correctly powered or not, set via the power system, return 1 if powered and 0 if not | |
| 1 | Powered | |||||
| Error | Boolean | Read
|
0 | 1 if device is in error state, otherwise 0 | ||
| 1 | Error | |||||
| On | Boolean | Read Write
|
0 | Off | The current state of the Logic Uplink. | |
| 1 | On | |||||
| RequiredPower | Integer | Read
|
||||
| PrefabHash | Integer | Read
|
||||
| ReferenceId | Integer | Read
|
||||
| NameHash | Integer | Read
|
||||