Actions

Editing Power Controller

Warning: You are not logged in. Your IP address will be publicly visible if you make any edits. If you log in or create an account, your edits will be attributed to your username, along with other benefits.

The edit can be undone. Please check the comparison below to verify that this is what you want to do, and then save the changes below to finish undoing the edit.
Latest revision Your text
Line 2: Line 2:
 
<translate>
 
<translate>
 
{{Itembox
 
{{Itembox
  | name        = Power Controller
+
  | name        = Area Power Controller
  | image      = [[File:ItemAreaPowerControl.png]]
+
  | image      = {{{image|[[File:ItemAreaPowerControl.png]]}}}
| stacks      = 5
 
| maxinpower  = 10W for the APC<br>+ 1000W Battery Charging<br>+ Output Load
 
| maxoutpower = No Limit
 
| createdwith = [[Electronics Printer]], [[Fabricator]]
 
| cost        = 5g [[Iron]], 2g [[Copper]], 3g [[Solder]]
 
}}
 
{{Structurebox
 
| name            = Area Power Controller
 
| power_usage      = 10W
 
| placed_with_item = [[Power Controller]]
 
| placed_on_grid  = Small Grid
 
| decon_with_tool1 = [[Hand Drill]]
 
| item_rec1        = [[Power Controller]]
 
 
}}
 
}}
 
== Description == <!--T:1-->
 
== Description == <!--T:1-->
The [[Power Controller|Area Power Controller]] is used to segregate power into their own subnetworks and reduce power fluctuations.
 
 
== Usage == <!--T:2-->
 
The APC can be opened with a [[Crowbar]], once opened the switch must be set to the 'ON' state for it to function. A [[Battery Cell]] can be added to act as a power buffer for the subnetwork in the event the main power network gets disconnected.
 
<br><br>
 
The APC can generally be used for machines with varying power requirements such as the Auto lathe, Electronics Printer, Fabricator, Arc Furnace, and more. This will allow all these machines to take lots of power in short intervals as long as the APC has a battery. Unlike the [[Transformer]], the APC will not limit the amount of power it passes through.
 
 
If sufficient power is available upstream, the APC acts as a pass through and will not limit it's output power, it is recommended to use a [[Fuse|Cable Fuse]] or [[Transformer|Transformer (Small)]] when powering a non-heavy cable network to prevent overdraw.
 
 
{{Data Network Header}} There is no difference in parameters, whether the logic network is connected to the input or output of the Area Power Control.
 
 
=== Mode Values ===
 
This shows the values of the "Mode" property, mapped to what the display will show.
 
{| class="wikitable"
 
|-
 
! Value !! Display !! Meaning
 
|-
 
| 0 || Grey || The Area Power Control is turned off or is missing a battery.
 
|-
 
| 1 || Red || No battery in the Area Power Control and there is power drawn from the output.
 
|-
 
| 2 || Blue-red blinking || There is a battery in the Area Power Control, the output draw is greater than the input and the battery is discharging.
 
|-
 
| 3 || Blue-green blinking || There is a battery in the Area Power Control, the output draw is less than the input and the battery is charging.
 
|-
 
| 4 || Green || There is a battery in the Area Power Control, the output draw is less than the input and the battery is fully charged.
 
|}
 
 
{{Data Parameters}}
 
{| class="wikitable"
 
|-
 
! Parameter Name !! Data Type !! Description
 
|-
 
| Open || Boolean || Opens the Area Power Control lid, when set to 1. Closes it, when set to 0.
 
|-
 
| Mode || Integer || Sets the mode to the passed value. This will only be set for less than a second, before the Area Power Control will override it with it's current mode. (See [[#Mode_Values|Mode Values]])
 
|-
 
| Lock || Boolean || Locks the Area Power Control, when set to 1. Unlocks it, when set to 0.
 
|-
 
| On || Boolean || Turns the Area Power Control on, when set to 1. Turns it off, when set to 0.
 
|}
 
 
{{Data Outputs}}
 
{| class="wikitable"
 
|-
 
! Output Name !! Data Type !! Description
 
|-
 
| Power || Boolean || Returns whether the Area Power Control is receiving power and is turned on. (0 for no, 1 for yes)
 
|-
 
| Open || Boolean || Returns whether the Area Power Control is open. (0 for no, 1 for yes)
 
|-
 
| Mode || Integer || Returns the current mode of the Area Power Control. (See [[#Mode_Values|Mode Values]])
 
|-
 
| Error || Boolean || Returns whether the Area Power Control is flashing an error. (0 for no, 1 for yes)
 
|-
 
| Lock || Boolean || Returns whether the Area Power Control is locked. (0 for no, 1 for yes)
 
|-
 
| Charge || Integer || Returns the currently available power, that can be output, in Watts. (Input power plus the charge of the battery in the Area Power Control.)
 
|-
 
| Maximum || Integer || Returns the maximum charge of the battery in the Area Power Control, in Watts.
 
|-
 
| Ratio || Float || Returns a range from 0.0 to 1.0. It returns the current charge percentage of the battery in the Area Power Control.
 
|-
 
| PowerPotential || Integer || Returns the current amount of power, available to the Area Power Control input, in Watts.
 
|-
 
| PowerActual || Integer || Returns the current amount of power, output by the Area Power Control, in Watts.
 
|-
 
| On || Boolean || Returns whether the Area Power Control is on. (0 for no, 1 for yes)
 
|-
 
| RequiredPower || Integer || Returns the current amount of power needed at the input, in Watts. (This includes the amount of power draw of the battery inside.)
 
|}
 
 
== History == <!--T:3-->
 
* In older versions of the game, the APC had specific Input and Output connection sides until a later update added a variant of the APC with reversed sides.
 
  
* In older versions of the game, a battery must be placed in the APC for it to function. This is no longer the case after the [https://steamcommunity.com/gid/103582791457826119/announcements/detail/1581192507757380156 power rework update] in v0.1.1062.5426 as you '''do not''' ''need'' a battery in the APC for it to function anymore.
+
<!--T:2-->
 +
The [[Power Controller|Area Power Controller]] is used to store small to medium amounts of power (depending on which cell you put in) and reduce power fluctuations.
  
 +
== Usage == <!--T:3-->
 +
Can be opened with a Crowbar. A battery must be placed in the APC and the switch must be set to 'ON' state for it to function.
 +
Currently, the dials in the APC do nothing.
 
</translate>
 
</translate>

Please note that all contributions to Unofficial Stationeers Wiki may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see Unofficial Stationeers Wiki:Copyrights for details). Do not submit copyrighted work without permission!

To edit this page, please answer the question that appears below (more info):

Cancel | Editing help (opens in new window)