Difference between revisions of "Pipe Analyzer"
From Unofficial Stationeers Wiki
(Fixed created with) |
|||
(3 intermediate revisions by 2 users not shown) | |||
Line 7: | Line 7: | ||
| image = [[File:ItemPipeAnalyizer.png]] | | image = [[File:ItemPipeAnalyizer.png]] | ||
| stacks = 5 | | stacks = 5 | ||
− | | createdwith = [[ | + | | createdwith = [[Hydraulic Pipe Bender]] |
| cost = 20g [[Iron_Ingot|Iron]], 2g [[Gold_Ingot|Gold]], 2g [[Copper_Ingot|Copper]], 2g [[Electrum_Ingot|Electrum]] | | cost = 20g [[Iron_Ingot|Iron]], 2g [[Gold_Ingot|Gold]], 2g [[Copper_Ingot|Copper]], 2g [[Electrum_Ingot|Electrum]] | ||
}} | }} | ||
Line 44: | Line 44: | ||
| RatioOxygen || Float || The ratio of oxygen in the pipe. A value between 0 (no oxygen at all, or 0%) and 1 ( pure oxygen atmosphere, or 100%) | | RatioOxygen || Float || The ratio of oxygen in the pipe. A value between 0 (no oxygen at all, or 0%) and 1 ( pure oxygen atmosphere, or 100%) | ||
|- | |- | ||
− | | RatioCarbonDioxide || Float || | + | | RatioCarbonDioxide || Float || ratio in mass percent / 100 |
|- | |- | ||
− | | RatioNitrogen || Float || | + | | RatioNitrogen || Float || ratio in mass percent / 100 |
|- | |- | ||
− | | | + | | RatioNitrousOxide|| Float || ratio in mass percent / 100 |
|- | |- | ||
− | | RatioVolatiles || Float || | + | | RatioPollutant || Float || ratio in mass percent / 100 |
+ | |- | ||
+ | | RatioVolatiles || Float || ratio in mass percent / 100 | ||
|- | |- | ||
| RatioWater || Float || | | RatioWater || Float || | ||
Line 56: | Line 58: | ||
| On || Boolean || | | On || Boolean || | ||
|- | |- | ||
− | | Requiredpower || Integer || In Watts. The Pipe Analyzer require | + | | Requiredpower || Integer || In Watts. The Pipe Analyzer require 5W of power to function |
+ | |- | ||
+ | | TotalMoles || Float || | ||
+ | |- | ||
+ | | Volume || float || | ||
+ | |- | ||
+ | | PrefabHash || float || | ||
+ | |- | ||
+ | | Combustion || bool || | ||
+ | |- | ||
+ | | RatioLiquidNitrogen || float || | ||
+ | |- | ||
+ | | VolumeOfLiquid || float || | ||
+ | |- | ||
+ | | RatioLiquidOxygen || float || | ||
+ | |- | ||
+ | | RatioLiquidVolatiles || float || | ||
+ | |- | ||
+ | | RatioSteam || float || | ||
+ | |- | ||
+ | | RatioLiquidCarbonDioxide || float || | ||
+ | |- | ||
+ | | RatioLiquidPollutant || float || | ||
+ | |- | ||
+ | | RatioLiquidNitrousOxide || float || | ||
|- | |- | ||
− | | | + | | ReferenceId || float || Globally Unique Device Identifier |
|} | |} | ||
</translate> | </translate> |
Latest revision as of 07:42, 14 April 2024
Properties | |
---|---|
Stacks | Yes (5) |
Recipe | |
Created With | Hydraulic Pipe Bender |
Cost | 20g Iron, 2g Gold, 2g Copper, 2g Electrum |
Description[edit]
Just like the Pipe Meter it can be used to display the pressure inside the pipes, but also displaying the contents and temperature. It requires 50W of power and can be hooked up to consoles or computers.
Data Network Properties[edit]
These are all Data Network properties of this device.
Data Parameters[edit]
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Lock | Boolean | |
On | Boolean |
Data Outputs[edit]
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | |
Error | Boolean | |
Pressure | Float | In kPa |
Temperature | Float | In Kelvin |
Lock | Boolean | |
RatioOxygen | Float | The ratio of oxygen in the pipe. A value between 0 (no oxygen at all, or 0%) and 1 ( pure oxygen atmosphere, or 100%) |
RatioCarbonDioxide | Float | ratio in mass percent / 100 |
RatioNitrogen | Float | ratio in mass percent / 100 |
RatioNitrousOxide | Float | ratio in mass percent / 100 |
RatioPollutant | Float | ratio in mass percent / 100 |
RatioVolatiles | Float | ratio in mass percent / 100 |
RatioWater | Float | |
On | Boolean | |
Requiredpower | Integer | In Watts. The Pipe Analyzer require 5W of power to function |
TotalMoles | Float | |
Volume | float | |
PrefabHash | float | |
Combustion | bool | |
RatioLiquidNitrogen | float | |
VolumeOfLiquid | float | |
RatioLiquidOxygen | float | |
RatioLiquidVolatiles | float | |
RatioSteam | float | |
RatioLiquidCarbonDioxide | float | |
RatioLiquidPollutant | float | |
RatioLiquidNitrousOxide | float | |
ReferenceId | float | Globally Unique Device Identifier |