Actions

Difference between revisions of "Kit (Blast Door) Blast Door"

From Unofficial Stationeers Wiki

(initial contents)
 
m (Characteristics & User Interface)
Line 14: Line 14:
 
<!--T:1-->
 
<!--T:1-->
 
==Description==
 
==Description==
A Blast Door is a powered [[Portal]] that will withstand extreme forces. They have no limit to the [[Pressure]] they can constrain, have a very high resistance to [[Damage]] and consumes #W of [[Power]] per [[Tick|Tick]]. Blast Doors can be used in the contruction of an [[Airlock]].  
+
A Blast Door is a powered [[Portal]] that will withstand extreme forces.
  
A Blast Door has separate [[Power Port]] and [[Data Port]] ports and indicator lights which will turn red if the door is locked and green if the door is unlocked. As long as the door is both unlocked and unpowered, it can be manually operated using a [[Crowbar|crowbar]].
+
<!--T:2-->
 +
==Characteristics==
 +
* It has no limit to the [[Pressure]] they can constrain.
 +
* It has a very high resistance to [[Damage]].
 +
* It consumes #W of [[Power]] per [[Tick|Tick]].
 +
* It can be used in the construction of an [[Guide (Airlock)|Airlock]].
 +
* It has a separate [[Power Port]] and [[Data Port]].
 +
* It has indicator lights.
 +
* If both unlocked and unpowered, it can be manually operated using a [[Crowbar]].
 +
* If enslaved by a [[Circuitboard (Airlock)|regular]] or a [[Circuitboard (Advanced Airlock)|advanced]] airlock circuit, it cannot be operated manually.
  
Since a Blast Door offers no option for manual operation, they must be controlled by one of:
+
As long as the door is both unlocked and unpowered, it can be manually operated using a [[Crowbar|crowbar]].
 +
 
 +
<!--T:3-->
 +
==User Interface==
 +
A Blast Door the following user interface:
 +
{| class="wikitable"
 +
|-
 +
! Name || Type !! Function
 +
|-
 +
| Lock || Indicator || Turns red when locked and green when unlocked
 +
|-
 +
|}
 +
 
 +
Since a Blast Door has no keypads to operate, they must be controlled by one of:
 
* [[Circuitboard (Advanced Airlock)]]
 
* [[Circuitboard (Advanced Airlock)]]
 
* [[Circuitboard (Airlock)]]
 
* [[Circuitboard (Airlock)]]
Line 25: Line 47:
 
* [[Motherboard (Logic)]] in a [[Computer]]
 
* [[Motherboard (Logic)]] in a [[Computer]]
  
<!--T:2-->
+
<!--T:4-->
 
==Construction==
 
==Construction==
 
A Blast Door is constructed using 1 x [[Kit (Blast Door)]].
 
A Blast Door is constructed using 1 x [[Kit (Blast Door)]].
  
<!--T:3-->
+
<!--T:5-->
 
==Deconstruction==
 
==Deconstruction==
 
A Blast Door can be deconstructed at any time using a [[Hand Drill]].
 
A Blast Door can be deconstructed at any time using a [[Hand Drill]].
Line 36: Line 58:
  
 
{{Data Parameters}}
 
{{Data Parameters}}
<!--T:4-->
+
<!--T:6-->
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
Line 49: Line 71:
  
 
{{Data Outputs}}
 
{{Data Outputs}}
<!--T:5-->
+
<!--T:7-->
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
Line 65: Line 87:
 
|}
 
|}
  
<!--T:6-->
+
<!--T:8-->
 
==See Also==
 
==See Also==
 
* [[Kit (Airlock)]]
 
* [[Kit (Airlock)]]

Revision as of 07:08, 20 March 2019


Blast Door
Blast door.jpg
Operation
Power Usage 25W
Burst Pressure Infinite
Construction
Placed with Kit (Blast Door)
Placed on Large Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Blast Door)

Description

A Blast Door is a powered Portal that will withstand extreme forces.

Characteristics

  • It has no limit to the Pressure they can constrain.
  • It has a very high resistance to Damage.
  • It consumes #W of Power per Tick.
  • It can be used in the construction of an Airlock.
  • It has a separate Power Port and Data Port.
  • It has indicator lights.
  • If both unlocked and unpowered, it can be manually operated using a Crowbar.
  • If enslaved by a regular or a advanced airlock circuit, it cannot be operated manually.

As long as the door is both unlocked and unpowered, it can be manually operated using a crowbar.

User Interface

A Blast Door the following user interface:

Name Type Function
Lock Indicator Turns red when locked and green when unlocked

Since a Blast Door has no keypads to operate, they must be controlled by one of:

Construction

A Blast Door is constructed using 1 x Kit (Blast Door).

Deconstruction

A Blast Door can be deconstructed at any time using a Hand Drill.

Data Network Properties

These are all Data Network properties of this device.

Data Parameters

These are all parameters, that can be written to with a Logic Writer, Batch Writer, or Integrated Circuit (IC10). The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.

Parameter Name Data Type Description
Open Boolean Opens the Blast Door, when set to 1. Closes it, when set to 0.
Lock Boolean Locks the Blast Door, when set to 1. Unlocks it, when set to 0.
On Boolean Turns the Blast Door on, when set to 1. Turns it off, when set to 0.

Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Power Boolean Returns whether the Blast Door is turned on and receives power. (0 for no, 1 for yes)
Open Boolean Returns whether the Blast Door is open. (0 for no, 1 for yes)
Lock Boolean Returns whether the Blast Door is locked. (0 for no, 1 for yes)
On Boolean Returns whether the Blast Door is turned on. (0 for no, 1 for yes)
RequiredPower Integer Returns the current amount of power, required by the Blast Door, in watts.

See Also