* It can withstand a [[Pressure]] differential of 1MPA.
 
* It can withstand a [[Pressure]] differential of 1MPA.
 
* It consumes 25W of [[Power]] per [[Tick]].
 
* It consumes 25W of [[Power]] per [[Tick]].
* It has separate [[Power Port]] and [[Data Port]].
+
* It has a separate [[Power Port]] and [[Data Port]].
 
* It has a keypad on both sides.
 
* It has a keypad on both sides.
 
* It has indicator lights.  
 
* It has indicator lights.  
 
* If unlocked, it can be manually operated using a [[Crowbar]] regardless of its power state.
 
* If unlocked, it can be manually operated using a [[Crowbar]] regardless of its power state.
* If enslaved by a [[Circuitboard (Airlock)|regular]] or a [[Circuitboard (Advanced Airlock)|advanced]] airlock circuit, it cannot be opened or closed manually.
+
* If enslaved by a [[Circuitboard (Airlock)|regular]] or a [[Circuitboard (Advanced Airlock)|advanced]] airlock circuit, it cannot be operated manually.
  
 
<!--T:3-->
 
<!--T:3-->
 
==User Interface==
 
==User Interface==
A powered [[Console]] equipped with a Circuitboard (Advanced Airlock) and will display the following user interface:
+
An Airlock provides the following user interface:
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
Line 34: Line 34:
 
| Keypad || Keypad  || Opens or closes the door as long as it has power
 
| Keypad || Keypad  || Opens or closes the door as long as it has power
 
|-
 
|-
| Lock || Indicator|| Turns red when locked and green when unlocked
+
| Lock || Indicator || Turns red when locked and green when unlocked
 
|-
 
|-
 
|}
 
|}

Revision as of 07:14, 20 March 2019


Airlock
Operation
Power Usage 25W
Construction
Placed with Kit (Airlock)
Placed on Large Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Airlock)

Description

An Airlock is a powered Portal suitable for use in constructing an airlock chamber. Guide (Airlock) provides additional information regarding the function, construction, and operation of airlocks.

Characteristics

  • It can withstand a Pressure differential of 1MPA.
  • It consumes 25W of Power per Tick.
  • It has a separate Power Port and Data Port.
  • It has a keypad on both sides.
  • It has indicator lights.
  • If unlocked, it can be manually operated using a Crowbar regardless of its power state.
  • If enslaved by a regular or a advanced airlock circuit, it cannot be operated manually.

User Interface

An Airlock provides the following user interface:

Name Type Function
Keypad Keypad Opens or closes the door as long as it has power
Lock Indicator Turns red when locked and green when unlocked

Construction

An Airlock is constructed using 1 x Kit (Airlock).

Deconstruction

An Airlock can be deconstructed at any time using a Hand Drill.

Data Network Properties

These are all Data Network properties of this device.

Data Parameters

These are all parameters, that can be written to with a Logic Writer, Batch Writer, or Integrated Circuit (IC10). The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.

Parameter Name Data Type Description
Open Boolean Opens the Airlock when set to 1. Closes it when set to 0.
Lock Boolean Locks the Airlock when set to 1. Unlocks it when set to 0.
On Boolean Turns the Airlock on when set to 1. Turns the Airlock off when set to 0.

Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Power Boolean Returns whether the Airlock is turned on and receiving power. (0 for no, 1 for yes)
Open Boolean Returns whether the Airlock is open. (0 for no, 1 for yes)
Lock Boolean Returns whether the Airlock is locked. (0 for no, 1 for yes)
On Boolean Returns whether the Airlock is turned on. (0 for no, 1 for yes)
RequiredPower Integer Returns the current watts of power required by the Airlock.

See Also