Editing Atmospheric Components Quick Reference
Warning: You are not logged in. Your IP address will be publicly visible if you make any edits. If you log in or create an account, your edits will be attributed to your username, along with other benefits.
The edit can be undone.
Please check the comparison below to verify that this is what you want to do, and then save the changes below to finish undoing the edit.
Latest revision | Your text | ||
Line 1: | Line 1: | ||
This is a quick reference to the various components of a piped-fluid network. | This is a quick reference to the various components of a piped-fluid network. | ||
− | {| class="wikitable | + | {| class="wikitable" |
|- | |- | ||
! Component !! Kit !! Inputs !! Outputs !! One-way? !! Switched? !! Compressor? !! Volume !! Max. Pressure !! Max. Power !! Primary Function | ! Component !! Kit !! Inputs !! Outputs !! One-way? !! Switched? !! Compressor? !! Volume !! Max. Pressure !! Max. Power !! Primary Function | ||
Line 15: | Line 15: | ||
| [[Pipe Volume Pump]] || [[Pipe Volume Pump|Kit (Volume Pump)]] || 1 || 1 || Yes || Yes || Yes, adjustable || varies? || ? || 800W, varies || Pump fluid at adjustable rate. | | [[Pipe Volume Pump]] || [[Pipe Volume Pump|Kit (Volume Pump)]] || 1 || 1 || Yes || Yes || Yes, adjustable || varies? || ? || 800W, varies || Pump fluid at adjustable rate. | ||
|- | |- | ||
− | | [[Pressure_Regulator#Pressure_Regulator|Pressure Regulator]] || [[Pressure Regulator|Kit (Pressure Regulator)]] || 1 || 1 || Yes || Yes || Yes || ? || 20 MPa | + | | [[Pressure_Regulator#Pressure_Regulator|Pressure Regulator]] || [[Pressure Regulator|Kit (Pressure Regulator)]] || 1 || 1 || Yes || Yes || Yes || ? || 20 MPa || 100W || Achieve target pressure at output. |
|- | |- | ||
− | | [[Pressure_Regulator#Back_Pressure_Regulator|Back Pressure Regulator]] || [[Pressure Regulator|Kit (Pressure Regulator)]] || 1 || 1 || Yes || Yes || Yes || ? || 20 MPa | + | | [[Pressure_Regulator#Back_Pressure_Regulator|Back Pressure Regulator]] || [[Pressure Regulator|Kit (Pressure Regulator)]] || 1 || 1 || Yes || Yes || Yes || ? || 20 MPa || 100W || Achieve target pressure at input. |
|- | |- | ||
| [[Pipe Meter]] || [[Pipe Meter|Kit (Pipe Meter)]] || colspan="2"|clamp-on || - || - || - || - || - || - || Visually show pipe's pressure. | | [[Pipe Meter]] || [[Pipe Meter|Kit (Pipe Meter)]] || colspan="2"|clamp-on || - || - || - || - || - || - || Visually show pipe's pressure. | ||
|- | |- | ||
− | | [[Pipe Analyzer]] || [[Pipe Analyzer|Kit (Pipe Analyzer)]] || colspan="2"|clamp-on || - || - || - || - || - || | + | | [[Pipe Analyzer]] || [[Pipe Analyzer|Kit (Pipe Analyzer)]] || colspan="2"|clamp-on || - || - || - || - || - || 50W || Sense pipe's pressure, temperature, and composition, for visual display and logic circuits. |
|- | |- | ||
| [[Pipe Gas Mixer]] || [[Pipe Gas Mixer|Kit (Gas Mixer)]] || 2 || 1 || Yes || Yes || Yes<sup>1</sup> || ? || ? || 100W || Mix fluids: Combine two input mixes into one output mix, at an adjustable ratio. | | [[Pipe Gas Mixer]] || [[Pipe Gas Mixer|Kit (Gas Mixer)]] || 2 || 1 || Yes || Yes || Yes<sup>1</sup> || ? || ? || 100W || Mix fluids: Combine two input mixes into one output mix, at an adjustable ratio. | ||
Line 31: | Line 31: | ||
| [[Kit (Atmospherics) Air Conditioner|Air Conditioner]] || [[Kit (Atmospherics)]] || 1 || 2 || Yes || Yes || Yes || ? || ? || 7,000W, varies || Heat or cool a fluid: From input, split heat between right-temperature and wrong-temperature outputs. | | [[Kit (Atmospherics) Air Conditioner|Air Conditioner]] || [[Kit (Atmospherics)]] || 1 || 2 || Yes || Yes || Yes || ? || ? || 7,000W, varies || Heat or cool a fluid: From input, split heat between right-temperature and wrong-temperature outputs. | ||
|- | |- | ||
− | | [[Wall Cooler]] || [[Wall Cooler|Kit (Wall Cooler)]] || | + | | [[Wall Cooler]] || [[Wall Cooler|Kit (Wall Cooler)]] || space || 1 || Yes, for heat<sup>2</sup> || Yes, for heat<sup>2</sup> || Yes, for heat<sup>2</sup> || ? || ? || ? || Cool a space: Actively remove heat from a space into a pipe. |
− | |||
− | |||
|- | |- | ||
| [[Pipe Radiator]] || [[Pipe Radiator|Kit (Pipe Radiator)]] || colspan="2"|clamp-on || - || - || - || - || - || - || Heat/cool: Passively exchange heat between a pipe and a space. | | [[Pipe Radiator]] || [[Pipe Radiator|Kit (Pipe Radiator)]] || colspan="2"|clamp-on || - || - || - || - || - || - || Heat/cool: Passively exchange heat between a pipe and a space. | ||
Line 73: | Line 71: | ||
'''Note 4:''' These Volume and Max. Pressure ratings reflect the limits of the removable canisters and tanks. Note that the 101 MPa limit of a Gas Canister is considerably higher than the 60 MPa overall limit of a pipe network. | '''Note 4:''' These Volume and Max. Pressure ratings reflect the limits of the removable canisters and tanks. Note that the 101 MPa limit of a Gas Canister is considerably higher than the 60 MPa overall limit of a pipe network. | ||
− | |||
− |