Editing Atmospheric Components Quick Reference
Warning: You are not logged in. Your IP address will be publicly visible if you make any edits. If you log in or create an account, your edits will be attributed to your username, along with other benefits.
The edit can be undone.
Please check the comparison below to verify that this is what you want to do, and then save the changes below to finish undoing the edit.
Latest revision | Your text | ||
Line 1: | Line 1: | ||
This is a quick reference to the various components of a piped-fluid network. | This is a quick reference to the various components of a piped-fluid network. | ||
− | {| class="wikitable | + | {| class="wikitable" |
|- | |- | ||
! Component !! Kit !! Inputs !! Outputs !! One-way? !! Switched? !! Compressor? !! Volume !! Max. Pressure !! Max. Power !! Primary Function | ! Component !! Kit !! Inputs !! Outputs !! One-way? !! Switched? !! Compressor? !! Volume !! Max. Pressure !! Max. Power !! Primary Function | ||
Line 13: | Line 13: | ||
| [[Pipe Digital Valve]] || [[Pipe Digital Valve|Kit (Digital Valve)]] || colspan="2"|2 generic || No || Yes || No || ? || ? || 25W || Open/close flow using [[Kit (Logic I/O)|logic circuits]]. | | [[Pipe Digital Valve]] || [[Pipe Digital Valve|Kit (Digital Valve)]] || colspan="2"|2 generic || No || Yes || No || ? || ? || 25W || Open/close flow using [[Kit (Logic I/O)|logic circuits]]. | ||
|- | |- | ||
− | | [[Pipe Volume Pump]] || [[Pipe Volume Pump|Kit (Volume Pump)]] || 1 || 1 || Yes || Yes || Yes | + | | [[Pipe Volume Pump]] || [[Pipe Volume Pump|Kit (Volume Pump)]] || 1 || 1 || Yes || Yes || Yes || varies? || ? || 800W, varies || Pump fluid at adjustable rate. |
|- | |- | ||
− | | [[Pressure_Regulator#Pressure_Regulator|Pressure Regulator]] || [[Pressure Regulator|Kit (Pressure Regulator)]] || 1 || 1 || Yes || Yes || Yes || ? || 20 MPa | + | | [[Pressure_Regulator#Pressure_Regulator|Pressure Regulator]] || [[Pressure Regulator|Kit (Pressure Regulator)]] || 1 || 1 || Yes || Yes || Yes || ? || 20 MPa || 100W || Achieve target pressure at output. |
|- | |- | ||
− | | [[Pressure_Regulator#Back_Pressure_Regulator|Back Pressure Regulator]] || [[Pressure Regulator|Kit (Pressure Regulator)]] || 1 || 1 || Yes || Yes || Yes || ? || 20 MPa | + | | [[Pressure_Regulator#Back_Pressure_Regulator|Back Pressure Regulator]] || [[Pressure Regulator|Kit (Pressure Regulator)]] || 1 || 1 || Yes || Yes || Yes || ? || 20 MPa || 100W || Achieve target pressure at input. |
|- | |- | ||
| [[Pipe Meter]] || [[Pipe Meter|Kit (Pipe Meter)]] || colspan="2"|clamp-on || - || - || - || - || - || - || Visually show pipe's pressure. | | [[Pipe Meter]] || [[Pipe Meter|Kit (Pipe Meter)]] || colspan="2"|clamp-on || - || - || - || - || - || - || Visually show pipe's pressure. | ||
|- | |- | ||
− | | [[Pipe Analyzer]] || [[Pipe Analyzer|Kit (Pipe Analyzer)]] || colspan="2"|clamp-on || - || - || - || - || - || | + | | [[Pipe Analyzer]] || [[Pipe Analyzer|Kit (Pipe Analyzer)]] || colspan="2"|clamp-on || - || - || - || - || - || 50W || Sense pipe's pressure, temperature, and composition, for visual display and logic circuits. |
|- | |- | ||
| [[Pipe Gas Mixer]] || [[Pipe Gas Mixer|Kit (Gas Mixer)]] || 2 || 1 || Yes || Yes || Yes<sup>1</sup> || ? || ? || 100W || Mix fluids: Combine two input mixes into one output mix, at an adjustable ratio. | | [[Pipe Gas Mixer]] || [[Pipe Gas Mixer|Kit (Gas Mixer)]] || 2 || 1 || Yes || Yes || Yes<sup>1</sup> || ? || ? || 100W || Mix fluids: Combine two input mixes into one output mix, at an adjustable ratio. | ||
Line 31: | Line 31: | ||
| [[Kit (Atmospherics) Air Conditioner|Air Conditioner]] || [[Kit (Atmospherics)]] || 1 || 2 || Yes || Yes || Yes || ? || ? || 7,000W, varies || Heat or cool a fluid: From input, split heat between right-temperature and wrong-temperature outputs. | | [[Kit (Atmospherics) Air Conditioner|Air Conditioner]] || [[Kit (Atmospherics)]] || 1 || 2 || Yes || Yes || Yes || ? || ? || 7,000W, varies || Heat or cool a fluid: From input, split heat between right-temperature and wrong-temperature outputs. | ||
|- | |- | ||
− | | [[Wall Cooler]] || [[Wall Cooler|Kit (Wall Cooler)]] || | + | | [[Wall Cooler]] || [[Wall Cooler|Kit (Wall Cooler)]] || space || 1 || Yes, for heat<sup>2</sup> || Yes, for heat<sup>2</sup> || Yes, for heat<sup>2</sup> || ? || ? || ? || Cool a space: Actively remove heat from a space into a pipe. |
− | |||
− | |||
|- | |- | ||
| [[Pipe Radiator]] || [[Pipe Radiator|Kit (Pipe Radiator)]] || colspan="2"|clamp-on || - || - || - || - || - || - || Heat/cool: Passively exchange heat between a pipe and a space. | | [[Pipe Radiator]] || [[Pipe Radiator|Kit (Pipe Radiator)]] || colspan="2"|clamp-on || - || - || - || - || - || - || Heat/cool: Passively exchange heat between a pipe and a space. | ||
Line 49: | Line 47: | ||
| [[Tank|Large Tank]] || [[Tank|Kit (Tank)]] × 5 || colspan="2"|1 generic || No || Logic only? || No || 50 kL || 60 MPa || - || Permanent, super-capacity fluid storage. | | [[Tank|Large Tank]] || [[Tank|Kit (Tank)]] × 5 || colspan="2"|1 generic || No || Logic only? || No || 50 kL || 60 MPa || - || Permanent, super-capacity fluid storage. | ||
|- | |- | ||
− | | [[Furnace]] || [[Furnace|Kit (Furnace)]], craftable at [[Autolathe]] || 1 || 1 || Yes || No || No || 1 kL || ? || - || Smelt ores, but can also melt/sublimate Ices directly into a pipe | + | | [[Furnace]] || [[Furnace|Kit (Furnace)]], craftable at [[Autolathe]] or [[Fabricator]] || 1 || 1 || Yes || No || No || 1 kL || ? || - || Smelt ores, but can also melt/sublimate Ices directly into a pipe. |
− | |||
− | |||
|} | |} | ||
− | '''Kit:''' The item used to build the component. These are the names as they appear in fabrication lists, which does not always match the true name of the item. Except where noted, all of these items are manufactured with a [[Hydraulic Pipe Bender]]. | + | '''Kit:''' The item used to build the component. These are the names as they appear in fabrication lists, which does not always match the true name of the item. Except where noted, all of these items are manufactured with a [[Hydraulic Pipe Bender]] or [[Fabricator]]. |
'''Input/Output:''' "Generic" connections are pipe fittings that are not explicitly for input or output. "Space" indicates an interface to fluids that are not contained in pipes (e.g., the atmosphere or the contents of a room). "Clamp-on" components have no fittings of their own; they clamp onto an existing Straight Pipe. | '''Input/Output:''' "Generic" connections are pipe fittings that are not explicitly for input or output. "Space" indicates an interface to fluids that are not contained in pipes (e.g., the atmosphere or the contents of a room). "Clamp-on" components have no fittings of their own; they clamp onto an existing Straight Pipe. | ||
Line 70: | Line 66: | ||
'''Note 2:''' The Wall Cooler's one-way, switched, and "compressor" qualities apply only to the heat exchange. It does not directly affect the pressure or flow in its attached pipe. | '''Note 2:''' The Wall Cooler's one-way, switched, and "compressor" qualities apply only to the heat exchange. It does not directly affect the pressure or flow in its attached pipe. | ||
− | '''Note 3:''' The Active Vent will ''fail'' at ? MPa. The pressure at which it will stop pumping is configurable through the data network and defaults to 0 Pa for | + | '''Note 3:''' The Active Vent will ''fail'' at ? MPa. The pressure at which it will stop pumping is configurable through the data network and defaults to 0 Pa for Outward mode and 101 kPa (1 standard atmosphere) for Inward mode. |
'''Note 4:''' These Volume and Max. Pressure ratings reflect the limits of the removable canisters and tanks. Note that the 101 MPa limit of a Gas Canister is considerably higher than the 60 MPa overall limit of a pipe network. | '''Note 4:''' These Volume and Max. Pressure ratings reflect the limits of the removable canisters and tanks. Note that the 101 MPa limit of a Gas Canister is considerably higher than the 60 MPa overall limit of a pipe network. | ||
− | |||
− |