Actions

Editing Air Conditioner

Warning: You are not logged in. Your IP address will be publicly visible if you make any edits. If you log in or create an account, your edits will be attributed to your username, along with other benefits.

The edit can be undone. Please check the comparison below to verify that this is what you want to do, and then save the changes below to finish undoing the edit.
Latest revision Your text
Line 137: Line 137:
 
|-
 
|-
 
| Lock || Boolean || Returns whether the Air Conditioner is locked. (0 for no, 1 for yes)
 
| Lock || Boolean || Returns whether the Air Conditioner is locked. (0 for no, 1 for yes)
|-
 
| Setting || Float || Target temperature setpoint in kelvin
 
|-
 
| Maximum || Float || Maximum temperature in kelvin
 
|-
 
| Ratio|| Float ||
 
 
|-
 
|-
 
| On || Boolean || Returns whether the Air Conditioner is turned on. (0 for no, 1 for yes)
 
| On || Boolean || Returns whether the Air Conditioner is turned on. (0 for no, 1 for yes)
 
|-
 
|-
 
| RequiredPower || Integer || Returns the current amount of power in Watts required by the Air Conditioner.
 
| RequiredPower || Integer || Returns the current amount of power in Watts required by the Air Conditioner.
|-
 
| PressureInput|| Float || Input pressure in kilopascals
 
|-
 
| TemperatureInput || Float || Input temperature in kelvin
 
|-
 
| RatioOxygenInput || Float || Percentage of Oxygen in input as ratio between 0 and 1
 
|-
 
| RatioCarbonDioxidenInput || Float || Percentage of Carbon Dioxide in input as ratio between 0 and 1
 
|-
 
| RatioNitrogenInput || Float || Percentage of Nitrogen in input as ratio between 0 and 1
 
|-
 
| RatioPollutantInput || Float || Percentage of Pollutant in input as ratio between 0 and 1
 
|-
 
| RatioVolatilesInput || Float || Percentage of Volatiles in input as ratio between 0 and 1
 
|-
 
| RatioWaterInput || Float || Percentage of Water in input as ratio between 0 and 1
 
|-
 
| RatioNitrousOxideInput || Float || Percentage of Nitrous Oxide in input as ratio between 0 and 1
 
|-
 
| TotalMolesInput|| Float || Total quantity of gas in input measured in moles
 
|-
 
| PressureOutput|| Float || Output pressure in kilopascals
 
|-
 
| TemperatureOutput || Float || Output temperature in kelvin
 
|-
 
| RatioOxygenOutput || Float || Percentage of Oxygen in output as ratio between 0 and 1
 
|-
 
| RatioCarbonDioxidenOutput || Float || Percentage of Carbon Dioxide in output as ratio between 0 and 1
 
|-
 
| RatioNitrogenOutput || Float || Percentage of Nitrogen in output as ratio between 0 and 1
 
|-
 
| RatioPollutantOutput || Float || Percentage of Pollutant in output as ratio between 0 and 1
 
|-
 
| RatioVolatilesOutput || Float || Percentage of Volatiles in output as ratio between 0 and 1
 
|-
 
| RatioWaterOutput || Float || Percentage of Water in output as ratio between 0 and 1
 
|-
 
| RatioNitrousOxideOutput || Float || Percentage of Nitrous Oxide in output as ratio between 0 and 1
 
|-
 
| TotalMolesOutput|| Float || Total quantity of gas in output measured in moles
 
|-
 
| PressureOutput2|| Float || Waste pressure in kilopascals
 
|-
 
| TemperatureOutput2 || Float || Waste temperature in kelvin
 
|-
 
| RatioOxygenOutput2 || Float || Percentage of Oxygen in waste as ratio between 0 and 1
 
|-
 
| RatioCarbonDioxidenOutput2 || Float || Percentage of Carbon Dioxide in waste as ratio between 0 and 1
 
|-
 
| RatioNitrogenOutput2 || Float || Percentage of Nitrogen in waste as ratio between 0 and 1
 
|-
 
| RatioPollutantOutput2 || Float || Percentage of Pollutant in waste as ratio between 0 and 1
 
|-
 
| RatioVolatilesOutput2 || Float || Percentage of Volatiles in waste as ratio between 0 and 1
 
|-
 
| RatioWaterOutput2 || Float || Percentage of Water in waste as ratio between 0 and 1
 
|-
 
| RatioNitrousOxideOutput2 || Float || Percentage of Nitrous Oxide in waste as ratio between 0 and 1
 
|-
 
| TotalMolesOutput2 || Float || Total quantity of gas in waste measured in moles
 
|-
 
| OperationalTemperatureEfficiency || Float || Ratio between 0 and 1 indicating that the unit is operating within its optimal temperature range
 
|-
 
| TemperatureDifferentialEfficiency || Float || Ratio between 0 and 1 that approaches 0 as the difference in temperature between the input and waste is too high
 
|-
 
| PressureEfficiency || Float || Ratio between 0 and 1 with efficiency reaching 1 when both input and waste pressure > 111.4575 kPa
 
 
|}
 
|}
  

Please note that all contributions to Unofficial Stationeers Wiki may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see Unofficial Stationeers Wiki:Copyrights for details). Do not submit copyrighted work without permission!

To edit this page, please answer the question that appears below (more info):

Cancel | Editing help (opens in new window)