Editing Active Vent
Warning: You are not logged in. Your IP address will be publicly visible if you make any edits. If you log in or create an account, your edits will be attributed to your username, along with other benefits.
The edit can be undone.
Please check the comparison below to verify that this is what you want to do, and then save the changes below to finish undoing the edit.
Latest revision | Your text | ||
Line 14: | Line 14: | ||
{{Structurebox | {{Structurebox | ||
| name = Active Vent | | name = Active Vent | ||
− | | power_usage = {{Icon|Energy|100}} ( | + | | power_usage = {{Icon|Energy|100}} (100W) |
| image = [[File:StructureActiveVent.png]] | | image = [[File:StructureActiveVent.png]] | ||
| paintable = Yes | | paintable = Yes | ||
Line 39: | Line 39: | ||
The "PressureExternal" values can also be inconvenient on worlds like Loulan whose atmosphere is well above 101kPa. Manually-operated airlocks can not equalise the pressure within the airlock during the exit cycle to the Loulan atmosphere pressures. Without equal pressures you can not prevent wind currents from occurring when opening airlock doors. The active vent has no effect when the external pressure within the airlock surrounding the active vent is already >101kPa. When the pressure is <101kPa the vent will stop when it reaches 101kPa. | The "PressureExternal" values can also be inconvenient on worlds like Loulan whose atmosphere is well above 101kPa. Manually-operated airlocks can not equalise the pressure within the airlock during the exit cycle to the Loulan atmosphere pressures. Without equal pressures you can not prevent wind currents from occurring when opening airlock doors. The active vent has no effect when the external pressure within the airlock surrounding the active vent is already >101kPa. When the pressure is <101kPa the vent will stop when it reaches 101kPa. | ||
− | The "PressureExternal" and "PressureInternal" values can be modified using [[Kit (Logic I/O)|logic chips]] or programmatically via IC10 scripts. | + | The "PressureExternal" |
+ | |||
+ | "PressureExternal" and "PressureInternal" values can be modified using [[Kit (Logic I/O)|logic chips]] or programmatically via IC10 scripts. | ||
'''Note''': These values reset to default values on mode change. Values can be set through logic chips, if the value is modified after a mode change. | '''Note''': These values reset to default values on mode change. Values can be set through logic chips, if the value is modified after a mode change. | ||
Line 52: | Line 54: | ||
Where (Inward vent): | Where (Inward vent): | ||
* P = Min(Room pressure, 10.1325 kPa) | * P = Min(Room pressure, 10.1325 kPa) | ||
− | * V = 8000 | + | * V = 8000 l |
* n = Moles per tick | * n = Moles per tick | ||
* R = Gas constant (8.3144) | * R = Gas constant (8.3144) | ||
Line 59: | Line 61: | ||
Where (Outward vent): | Where (Outward vent): | ||
* P = Min(Pipe pressure, 10.1325 kPa) | * P = Min(Pipe pressure, 10.1325 kPa) | ||
− | * V = Pipe volume in | + | * V = Pipe volume in l |
* n = Moles per tick | * n = Moles per tick | ||
* R = Gas constant (8.3144) | * R = Gas constant (8.3144) | ||
Line 103: | Line 105: | ||
'''Note''': The value of "PressureExternal" and "PressureInternal" will be reset to the default when changing modes. | '''Note''': The value of "PressureExternal" and "PressureInternal" will be reset to the default when changing modes. | ||
− | |||
'''Note''': If turned on, the vent will still consume energy when the target pressure is reached. | '''Note''': If turned on, the vent will still consume energy when the target pressure is reached. | ||