Actions

Purge Valve

From Unofficial Stationeers Wiki

Revision as of 14:53, 18 May 2025 by 188.68.106.223 (talk)
Purge Valve
Purge Valve.png
Operation
Power Usage 100W
Prefab Hash -737232128
Prefab Name StructurePurgeValve
Construction
Placed with Kit (Pressure Regulator)
Placed on Small Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Pressure Regulator)


Description

Allows for removal of pressurant gas and evaporated liquids from a liquid pipe. Similar in function to a Back Pressure Regulator the Purge Valve moves gas from the input liquid pipe to the output gas pipe aiming to keep the pressure of the input at the target setting.
- Stationpedia

Purge Valve is an active powered device for controlled transfer of substances between the two pipe networks. Purge Valve will drain the gas from Input liquid pipe network and transfer it to the Output gas pipe network until a pressure limit defined by the valve setting is reached on Input network. Setting the pressure limit to 0 will pump the gases out completely, leaving only the liquids behind. When being placed, hologram indicators will display the Input liquid pipe arrow inward, the Output gas pipe arrow outward, and the power socket on its side. It has a pressure control valve, which defines the pressure limit.

Purge Valves are often used to collect a substance evaporated from its liquid state (such as Nitrous Oxide, often stored in its liquid form) before its practical use. Othar than that, it can be utilized to remove any undesired gas constituents from a liquid pipe. Used in conjunction with a Pressurant Valve, Purge Valve can be used to precisely control the pressure within a liquid pipe network for complex phase change operations.

Note: The evaporated liquid drained using the Purge Valve can inadvertedly begin to turn back into a liquid within the output gas pipe network if conditions commands it, which may cause the pipes to flood and burst. Caution is advised.

Data Network Properties

These are all Data Network properties of this device.

Data Parameters

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).

Click here to see/hide all the data network properties
Parameter Name Data Type Access Value Description
Power Boolean
Read
0 Unpowered Can be read to return if the Purge Valve is correctly powered or not, set via the power system, return 1 if powered and 0 if not
1 Powered
Error Boolean
Read
0

1 if device is in error state, otherwise 0
1 Error
Lock Boolean
Read Write
0 Unlocked Disable manual operation of the Purge Valve.
1 Locked
Setting Integer
Read Write
0.0 to 60795.0 A variable setting that can be read or written.
Maximum Float
Read
Maximum setting of the Purge Valve
Ratio Float
Read
0.0 to 1.0 Context specific value depending on device, 0 to 1 based ratio
On Boolean
Read Write
0 Off The current state of the Purge Valve.
1 On
RequiredPower Integer
Read
Idle operating power quantity, does not necessarily include extra demand power
PrefabHash Integer
Read
The hash of the structure
ReferenceId Integer
Read
Unique Reference Identifier for this object
NameHash Integer
Read