Actions

Back Pressure Regulator

From Unofficial Stationeers Wiki

Revision as of 06:00, 10 July 2024 by Emilgardis (talk | contribs)
Back Pressure Regulator
File:StructureBackPressureRegulator.png
Operation
Power Usage 100W
Prefab Hash -1149857558
Prefab Name StructureBackPressureRegulator
Construction
Placed with Kit (Pressure Regulator)
Placed on Small Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Pressure Regulator)


Description

Unlike the Pressure Regulator, which closes when the input exceeds a given pressure, the back pressure regulator opens when input pressure reaches a given value.
- Stationpedia

The Back Pressure Regulator will only pass through gases when the pressure on its intake side exceeds the set value. In other words, the standard Regulator defaults open and closes when the output is overpressured, while the Back Pressure Regulator defaults closed and opens when the input is overpressured.

Like the standard Regulator, the Back Pressure Regulator also acts as a check valve, switched valve, and compressor (i.e., input gas will move even if the output is already a higher pressure).

The maximum pressure that can be set is 60795 kPa.

Its low flow rate makes it not suitable for being used as an emergency dump valve.

To calculate the moles per tick, use the following equation: n = (P * V) / (R * T)

Where:

  • P = Min(Input pressure, 101.325)
  • V = 100
  • n = Moles per tick
  • R = Gas constant (8.3144)
  • T = Input temperature

Data Network Properties

These are all Data Network properties of this device.

Data Parameters

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).

Click here to see/hide all the data network properties
Parameter Name Data Type Access Value Description
Power Boolean
Read
0 Unpowered Can be read to return if the Back Pressure Regulator is correctly powered or not, set via the power system, return 1 if powered and 0 if not
1 Powered
Error Boolean
Read
0

1 if device is in error state, otherwise 0
1 Error
Lock Boolean
Read Write
0 Unlocked Disable manual operation of the Back Pressure Regulator.
1 Locked
Setting Integer
Read Write
0.0 to 60795.0 A variable setting that can be read or written.
Maximum Float
Read
Maximum setting of the Back Pressure Regulator
Ratio Float
Read
0.0 to 1.0 Context specific value depending on device, 0 to 1 based ratio
On Boolean
Read Write
0 Off The current state of the Back Pressure Regulator.
1 On
RequiredPower Integer
Read
Idle operating power quantity, does not necessarily include extra demand power
PrefabHash Integer
Read
The hash of the structure
ReferenceId Integer
Read
Unique Reference Identifier for this object
NameHash Integer
Read
Provides the hash value for the name of the object as a 32 bit integer.