Actions

Air Conditioner

From Unofficial Stationeers Wiki

Revision as of 20:22, 18 October 2019 by Ipottinger (talk | contribs)


Air Conditioner
Atmospherics front.jpg
Operation
Power Usage Up to 7000W based on temperature difference
Construction
Placed with Kit (Atmospherics)
Placed on Small Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Atmospherics)

Purpose

An Air Conditioner is a powered Atmospheric processor used to lower and raise the temperature of gases passed through it. Guide (Air Conditioning) provides additional information regarding the function, construction, and operation of an Air Conditioner.

Characteristics

  • It has a manual power switch.
  • It consumes 5W of Power per Tick when idle.
  • It consumes a maximum of 7kW of Power per Tick when active.
  • It has a separate Power Port and Data Port.
  • It has a touchpad that provides manual temperature control.
  • It has a pipe port (labelled "Input") for the gases that will be heated or cooled to the designated temperature.
  • It has a pipe port (labelled "Output") for the gases that have been heated or cooled to the designated temperature.
  • It has a pipe port (labelled "Waste") for gases to or from which heat will be transferred to raise or lower the input gases' temperature.
  • If the Waste pipe network is below 100kpa, input gases will be diverted to the Waste pipe network to raise its pressure.
  • It can raise or lower gas temperature within a range from -99°C to 99°C.

User Interface

An Air Conditioner provides the following user interface:

Name Type Function
Temperature Display Displays the current output temperature setting
+ Touchkey Increase the current output temperature setting by 10°C and by 1°C with the Quantity Modifier key pressed.
- Touchkey Decrease the current output temperature setting by 10°C and by 1°C with the Quantity Modifier key pressed.
Start Touchkey Switches Air Conditioner between idle and active.
On/Off Switch Switches Air Conditioner between turned on or turned off.

Data Network Properties

These are all Data Network properties of this device.

Data Parameters

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).


Parameter Name Data Type Description
Open Boolean Activates the Air Conditioner when set to 1. Idles it when set to 0.
Mode Integer (Unknown) (Judging by the "Mode" output, it accepts values in the range 0-2.)
Lock Boolean Locks the Air Conditioner when set to 1. Unlocks it when set to 0.
On Boolean Powers on the Air Conditioner on when set to 1. Powers off when set to 0.

Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Power Boolean Returns whether the Air Conditioner is turned on and receives power. (0 for no, 1 for yes)
Open Boolean Returns whether the Air Conditioner is active or idle. (0 for no, 1 for yes)
Mode Integer (Unknown) (Returns output in the range 0-2, equivalent to the input of the "Mode" parameter.)
Error Boolean Returns whether the Air Conditioner is flashing an error. (0 for no, 1 for yes)
Lock Boolean Returns whether the Air Conditioner is locked. (0 for no, 1 for yes)
On Boolean Returns whether the Air Conditioner is turned on. (0 for no, 1 for yes)
RequiredPower Integer Returns the current amount of power in Watts required by the Air Conditioner.

See Also